Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. TROUBLESHOTING

Problem
Does not heat
Mixing paddle does not turn
Tap leaks
Water is escaping from the
level tank
Product leaks from the bottom
of the transparent bowl
The thermometer does not
show the temperature
Machine shutdown
If the machine malfunctions due to causes other than those listed in this table or the proposed remedies do not solve the problem, contact a specialized
technician
SL310006533 Ed.00 - 03/2016
Cause
No power
Switch set to -OFF-
Thermoprobe intervention
Thermostat on "0"
No power
The driving shaft is not properly in place
Motor fault
On/off switch on (0).
It has not been fit correctly
The outlet and rubber are dirty
The sealing gasket needs replacing
Temperature too high
The sealing gasket of the level tube needs replacing
The water level is above the MAX indication when the
machine is at room temperature
The bowl has not been fit correctly in place
The seal needs replacing
Flat battery
Probe malfunction
The water level in the boiler tank has fallen below the
minimum level with resulting machine shutdown
No water in the boiler tank
Remedy
Make sure that the machine is plugged in properly
Set the switch to -ON-.
Reset the thermal protector as directed in section 6.1.
Adjust the thermostat
Make sure that the machine is plugged in properly
Remove the shaft and then insert it correctly as directed in section
7.5.2.
Contact service personnel
Press the switch on
Empty the machine and fit the tap as directed in section 7.5.3.
Empty the machine and clean the entire tap thoroughly; fit it back on
the machine as directed in section 7.5.1.
Contact service personnel
Lower the temperature
Contact service personnel
Allow the machine to cool down and empty the boiler until reaching the
level indicated
Empty the machine, remove the bowl and fit it in place according to the
instructions provided in section 7.5.2.
Contact service personnel
Replace the battery, paragraph 7.9.
Call a specialized technician
Top up the boiler tank, if a level sensor is fitted
Call for a specialized technician to reset the machine
Top up the boiler tank, if a level sensor is fitted
Call for a specialized technician to reset the machine
- 21_EN -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Chocolady cl-5cl-10

Table des Matières