4.4 Mixer positioning and mounting
H1
min
L
H2
min
min
min 5 m
min 200 mm
In tanks with aeration, an unaerated area of at least 5 m must be provided on
the bottom at each side of the unit.
The unaerated area will ensure that the unit is able to operate correctly.
Ø Propeller
H2
min
Safety, Installation and Operations Manual – Translation of original instructions
H1min
H2min
mm
mm
mm
200
400
200
300
500
300
450
750
450
550
750
550
650
1000
650
800
1000
800
NOTE: To allow the unit to be passed over the parapet, there
must be a clearance of 1.2 m between the top edges of the
parapet and the crane lifting point.
Lmin
mm
300
450
675
825
975
1200
EN
29