9. If the lower air tube is too long, trim the tube so that it fits the
gun.
10. Push the lower air tube onto the bottom of the check valve.
NOTE: Make sure to attach the shorter air tube to the gun
fitting and the longer air tube to the cup lid air
nipple.
Replacing the Cup Gasket
The cup gasket must be replaced periodically due to normal wear. It is
important to inspect the cup gasket during each cleaning.
1. Release the cup locking lever.
2. Hold the cup and twist the spray gun in the direction
indicated by the arrows on the bridge.
3. Lift the spray gun away from the cup.
4. Pull the worn cup gasket out of the lid.
5. Press a new cup gasket into the lid.
6. Place the spray gun onto the top of the cup.
Bridge
Cup Gasket
7. Turn the spray gun opposite the direction indicated by the
arrows on the bridge until the pegs on the cup are in the
notches of the bridge.
8. Tighten the cup locking lever.
© Titan Tool Inc. All rights reserved.
Valve Seal
Air Tube
Check Valve
Air Tube
Cup Locking
Lever
Swivel Lever
Lid
Converting to a Single Pin Trigger
The trigger on your HVLP spray gun can be converted to a single pin
setup for a softer pull. Trigger pull is reduced by removing the upper
trigger pin and operating the gun with only the lower trigger pin in
place. This setup reduces finger fatigue and provides greater control
when spraying thin, light viscosity materials such as stains, varnishes,
and sealers.
1. Remove the retaining clip
on the upper trigger pin
by placing the flat edge of
a screwdriver between the
clip and the pin and gently
prying it off.
2. Pull the trigger pin out
from the opposite side of
the gun.
Using a Pressure Feed
System
To increase spray time between material refills, your HVLP spray
gun can be connected to a larger material pressure pot and air
compressor.
Converting the Gun to Pressure Feed
Before using a pressure feed system, the spray gun must be
converted to a pressure fed gun.
1. Loosen the retaining nut using a wrench and remove the one
quart cup assembly.
2. Pull the air tube off of the air tube fitting on the spray gun.
3. Remove the air tube fitting using a wrench.
4. Thread the set screw into the air tube fitting location and
tighten into place.
OPTIONAL (in place of steps 3 and 4): If desired, a temporary cap
(also included) can be used to close off the air tube fitting rather
than performing steps 3 and 4 above.
Air Tube
Fitting
Set
Screw
7
Air Tube
Retaining Nut
Cup Assembly
Air Tube
Cap