Télécharger Imprimer la page

Titan Maxum II Notice D'utilisation page 8

Publicité

Les langues disponibles

Les langues disponibles

Connecting to a 2-Quart Remote Pressure Pot
1. Convert the gun to pressure feed.
2.
Connect hoses:
a. Make sure turbine is turned OFF and unplugged.
b. Attach remote pressure pot to the turbine via the hose
configuration shown below.
c. Tighten the air hose connections by hand.
b. Tighten the fluid hose connections with an adjustable
wrench.
1) Turbine
2) 7.5m air hose
3) Female quick-disconnect coupling
4) 2-quart pressure tank assembly
5) 1.5m air whip hose
6) 1.5m fluid whip hose
7) Hose straps
8) Female quick-disconnect coupling
9) Spray gun
2
3
1
4
Converting the Gun to a Regulator Gun
Your HVLP spray gun can be converted to connect directly to existing
high pressure air systems with the addition of a regulator assembly.
1. Remove the air inlet fitting at the bottom of the gun handle
using a wrench.
2. Thread the fitting on the regulator assembly into the air inlet
at the bottom of the gun handle and tighten.
Air Inlet
Fitting
3. Attach the air hose from the existing high pressure air system
to the regulator assembly.
4. Set the pressure gauge on the regulator assembly to the
appropriate setting for the coating being sprayed.
NOTE: Standard air caps require an air flow of 15 – 25 SCFM.
Low air flow air caps are available for the regulator
gun to use with smaller air compressors. See
"Optional Accessories" for the part numbers.
English
9
8
5
7
6
Regulator
Assembly
Converting the gun from Non-Bleeder to
Bleeder
Your HVLP spray gun can be converted from a non-bleeder to a bleeder
setup. Bleeder setup provides more atomizing power for higher
viscosity materials, such as latex and enamels. Bleeder setup can make
it easier to spray in confined spaces, such as inside cabinets, because the
air hose is moved to the back of the gun.
To convert a spray gun to bleeder setup:
1. Remove the air flow adjustment knob from the rear of the gun
using a wrench.
2. Remove the air inlet fitting from the bottom of the gun handle
using a wrench.
3. Thread the air inlet fitting into the air flow adjustment knob
location at the rear of the gun. Secure the fitting in place.
Air Flow
Adjustment
Knob
4. Thread the air inlet plug (shipped loose with the gun literature
pack) into the air inlet at the bottom of the gun handle.
Secure the plug in place.
Air Inlet
Plug
5. Attach the air hose to the relocated air inlet fitting.
NOTE: In bleeder setup, the removal of the air flow
adjustment knob causes the air supply to be on at all
times when the air hose is attached to the gun.
8
Air Inlet
Fitting
© Titan Tool Inc. All rights reserved.

Publicité

loading

Ce manuel est également adapté pour:

02770340277057027707602770880524041