Operation of the height adjustable, support arm system (flexion-port)
on the monitor shelf, 2-fold
When operating the height adjustable, support arm system (flexion-port) aon the monitor shelf,
2-fold, always make sure that the swivelling arm that provides the changeover, is always placed
parallel to the front side of the cart (engaged position). Thereby, please observe that only two
operating positions of the support arm (right / left) are permitted (refer to "Operating position" in
Chapter "1.2 General symbol explanation", Page 31).
By a changeover of the operating position from left to right, or vice versa, the locking elements
must be pushed downwards and the height adjustable support arm swivelled to the other side.
Hereby, for flexion-port with swivelling arm make sure that it is folded when changing over.
Otherwise, the tilting stability cannot be guaranteed (refer to Point 2.4).
7
Miscellaneous
7.1
Disinfection
The uni-cart, pro-cart, duo-cart, compact-cart, classic-cart or endo-cart should be cleaned
with a suitable neutral cleaning agent and disinfected using a disinfectant or 30% alcohol
solution. The cart cannot be sterilized.
Permissible disinfection and cleaning agents are as follows:
Cidex, Aldasan 200, Kohrsolin, Mellsitt, Gigasept FF, Lysoformin spezial, Spray Activ, Terralin,
Quartamon Med, Mikrozid Liquid, Fairy, Pril, Palmolive
7.2

Attachment and explanation of the symbols on the cart

Operating manual uni-cart, pro-cart, duo-cart, compact-cart, classic-cart and endo-cart 03/2011
Equipotential bonding:
Identifies equipotential bonding terminals on the housing of the isolating transformer,
equipotential bonding ensures that resistance between all conductive materials is
sufficiently low.
Connection to protective conductor:
Connects conductors, equipment units, conducting parts, main earth terminals
and earth.
Conductive castors:
Conductive castors are indicated by a flash or a yellow point