N.B.: if no encoder is installed, time based control is used.
reconnect to mains power.
No encoder installed.
Optical encoders installed (8 pulses/revolution).
E30 Series. Magnetic encoders installed (1 pulse/revolution)
R21 series (version V.1). Magnetic encoders installed (1 pulse/revolution).
STEP MODE.
PARTIAL OPENING
OPENING
CLOSING.
STOP.
Courtesy light. The output COR is managed from the remote control. The light remains lit as long as the
remote control is active. The parameter
Courtesy light ON-OFF (PP). The output COR is managed from the remote control.
The remote control turns the courtesy light on and off. The parameter
FLASHING LIGHT. The FLASHING LIGHT output is managed from the remote control. The light remains lit
as long as the remote control is active. The parameter
FLASHING LIGHT ON-OFF. The FLASHING LIGHT output is managed from the remote control.
The remote control turns the courtesy light on and off. The parameter
Selecting courtesy light mode
Disabled.
ACTIVE. The light remains lit for the entire duration of the manoeuvre.
From 3 to 90 s. The light remains lit for the time period set after the manoeuvre is completed.
From 2 to 9 minutes. The light remains lit for the time period set after the manoeuvre is completed.
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock), the gate closes.
When the clock function is active, the gate opens and remains open. Any command signal received is ignored.
When the clock function is active, the gate opens and remains open. Any command signal received is
accepted. When the gate returns to the completely open position, the clock function is reactivated.
Restoring factory default values
NOTE This procedure is only possible is NO data protection password is set.
buttons until the unit switches on.
• The message
• The default factory settings have now been restored.
72
+
P1
P2
-
x4 s
flashes on the display after 4 s.
is ignored.
is ignored.
Warning! Restoring default settings cancels all settings
are suitable for the installation.
The default factory settings may also be restored using
the + (PLUS) and/or -
Turn off the power.
Press and hold the + (PLUS) and - (MINUS)
is ignored.
is ignored.