Set initial acceleration when opening/closing (soft-start)
Disabled.
Enabled. The gate accelerates slowly and progressively at the start of the manoeuvre.
Enabled. The gate accelerates even more slowly and progressively at the start of the manoeuvre.
recommended for heavy gates.
Set motor torque after activation of sensing edge or encoder
Disabled. Torque applied is the value set for parameter
1 = minimum motor torque ... 8 = maximum motor torque.
Enable maximum torque boost at start of manoeuvre
If this parameter is enabled, each time the motor starts the maximum boost torque is applied for a setta-
ble period of time to allow the gate to start moving.
From 0 to 20 s.
Set open/closed stop approach distance
Disabled.
= 0.5 m long gate leaf;
gate vibration when it reaches the stop.
travel to ensure that the lock latches correctly. On installations with no electric lock, the torque applied is
Enable electric lock release reverse impulse
Disabled.
Enabled. At the start of each opening manoeuvre, the control unit applies a brief closing force (settable
from 1 to 4 s) to release the electric lock.
Enabling the electric lock release reverse impulse function automatically enables parameters
(electric lock lead time = 1 s) and
Set deceleration during opening/closure
Disabled.
Medium deceleration.
N.B.
Maximum deceleration. IMPORTANT
DO NOT USE 6 pole motors (R20/302, R20/502, R21/368, H23/282, R41/832, R41/833).
Set obstacle detection sensitivity during manoeuvres
The gate reverses immediately when an obstacle is detected during an opening or closing manoeuvre.
NOTE
Set obstacle detection sensitivity during deceleration
The gate reverses immediately when an obstacle is detected during opening or closing deceleration.
NOTE
From 1% to 99%.
= minimum sensitivity ...
Setting number of automatic closure attempts after activation of sensing edge
or obstacle detection (crush protection)
No automatic closure attempts.
From 1 to 3 automatic closure attempts.
We recommend setting a value equal to or lower than the value set for parameter
Automatic closure is only performed if the gate is completely open.
different from
= 1 m long gate leaf;
= 1.5 m long gate leaf;
(electric lock activation time = 3 s).
ONLY in oustanding possibilities, for example gates very light.
for 6-pole slow motors (
for 6-pole slow motors (
= maximum sensitivity.
). Setting a value of
.
= 2 m long gate leaf;
.
).
).
is not
.
69