LAW 9IMR - LAW 14ITR
Fig. 5.4
Installation on wall brackets is not advisable, as this frequently
leads to noise problems.
If this type of installation is used, observe the following instruc-
tions:
Fit rubber buffers
Take the weight of the outdoor unit into account
Ensure that the wall bracket is no higher than 1 m above
the ground
Ensure that minimum clearances are adhered to
Fig. 5.5
www.gdts.one
5.2.1 Wall opening for split lines and
electric wires
Please proceed as follows when laying split lines and elec-
tric wires:
Drill a 70 mm opening for the pipework using a core drill
The opening for the pipework should be slightly inclined
towards the outdoor unit, so that no rainwater can pene-
trate the building.
Indoor unit
5.2.2 Wall opening for condensate drain
Outdoor unit
452162.66.04 · FD 9912
Wall
Outdoor unit
Wall
Indoor unit
English
EN-5