Switching on and off

Switching on:
First, press the trigger lock
then the trigger
Switching off:
Release the trigger
When you have finished working, disconnect
the tool from the compressed air source .

Maintenance and cleaning

WARNING! RISK OF INJURY!
Disconnect the tool from the
compressed air supply.
CAUTION!
Before maintenance, clean off any hazardous
substances that may have accumulated on
the tool (due to working processes) . Avoid
all skin contact with these substances . If the
skin comes into contact with hazardous dusts,
this can lead to severe dermatitis . If dust is
produced or swirled up during maintenance,
it can be inhaled .
NOTE
To ensure correct functioning and a long
service life for the tool, pay attention to the
following points:
Sufficient and continuous oil lubrication is highly
important for optimum functioning .
Check the speed and vibration levels after each
use .
Check the idle speed regularly and after any
maintenance is performed:
use a rev counter and perform the measure-
ment without any clamped tools . At a residual
pressure of 6 .3 bar, the idle speed may not be
exceeded under any circumstances .
22 
GB │ IE
All manuals and user guides at all-guides.com
forwards and
down to switch the tool on .
.
If the tool is exhibiting excessive vibration levels,
the cause of the vibrations must be identified
and repaired .
Use only the genuine replacement parts recom-
mended by the manufacturer, otherwise you
could put users at risk . In doubt, contact the
Service Centre .
Clean the tool with a soft, dry cloth only .
Never use sharp or abrasive cleaning agents
under any circumstances .

Troubleshooting

Fault
Possible
cause
Speed too
Motor parts
slow, air
jamming due
escapes from
to dirt .
the outlet .
Pressure sup-
ply too low .
Tool does
Motor is
not move;
jammed due
compressed
to material
air escapes
build-up .
completely
through the
outlet .
Remedy
Check the
pressure sup-
ply filter for
contamination .
Check the
pressure sup-
ply filter for
contamination .
Lubricate the
tool as de-
scribed in the
instructions .
If necessary,
repeat the
steps outlined
above .
Lubricate the
tool as de-
scribed in the
instructions .