5 . Green LEDs notifying intensity of signal received . A correctly
received signal is made up of at least 3 bars .
6 . [SW1] 8 dipswitches for:
[1 . .4] setting the module address;
[5] activation of LEDs (ON active);
[6,7] not used;
[8] disabling anti-tear tamper (ON disabled) .
7 . [R] Button to restart receiver (e .g . after change of address) .
8 . [M] Button not used .
9 . [SW2] Anti-opening tamper .
10 . [SW3] Anti-tear tamper .

INSTALLATION

The receiver is to be mounted in sheltered spaces and in the most
suitable position for receiving the radio signal from the various
devices connected .
Connect the control unit and receiver to the respective terminals
[+ A B -] .

ADDRESSING

The local radio module has address 01, so the modules connected
on the bus can be set at address 02 or 03