[T, +] terminals for connecting the control unit tamper .
[JP3] link to enable/disable the tamper (position C to disa-
D
ble the control unit tamper, position O to enable it)
E
[PE] terminal for earthing
[L, L] terminals for external PSTN telephone line input
6
[T, T] terminals for PSTN telephone line output to phone or
switchboard
[CN2] connector for GSM module
[F4] for PXC48: no fuse .
G
[F4] for PXC96: self-restoring 1 .35 A fuse
[F4] for PXC200: self-restoring 1 .35 A fuse
Dip 1 is used to move the control unit over from
service to maintenance (ON= Maintenance, OFF= Service)
Dip 2 is used to restore the Codes to factory set-
tings .
8
Dip 3 is used to restore to factory settings
Dip 4 is used to programme the control unit firm-
ware
[P1] button to restart the control unit (it is not used to re-
I
store parameters; it does not alter the settings) .
[CN3] connector for voice guide PXV64/PXV256 and lan-
J
guages card .

Wall mounting

PXC48
Install the control unit far from access points and somewhere it is hard to identify .
Secure onto a suitable wall that can permanently support the control unit .
Prepare the holes and channel for the cables to pass through before installation .
Use the 4 special holes for mounting it on the wall .
[CN1] Female RS-232 socket for connection to PC (via a
straight male-female RS-232 cable) or to the Ethernet in-
terface .
K
[F4] for PXC48: no fuse .
[F4] for PXC96: self-restoring 1 .35 A fuse .
[F4] for PXC200: self-restoring 1 .35 A fuse .
[JP2] link to supply Ethernet interface connected to con-
nector CN1 (enables the 12 V DC on connector CN1 (RS-
L
232) on pin 9) . Position A = enabled 12 V DC; Position B =
disabled 12 V DC .
[F1] for PXC48: glass T fuse, 3 .15 A .
[F1] for PXC96: glass T fuse, 3 .15 A .
M
[F1] for PXC200: glass T fuse, 3 .5 A .
[V AC] terminals for connection to transformer .
N
[CN7] connector for battery .
[F2] for PXC48: self-restoring 1 .6 A fuse .
O
[F2] for PXC96: self-restoring 2 .5 A fuse .
[F2] for PXC200: self-restoring 3 A fuse
If installed, the PXSTB is a temperature sensor that opti-
mises battery recharging .
[PXSTB] connector for PXSTB sensor .
P
Q
[JP1] link to enable (PXSTB and link NOT present) or disable
(no PXSTB and link present) the PXSTB sensor .
[CN5] connector for input expansion in control unit .
[F3] for PXC48: no fuse .
R
[F3] for PXC96: self-restoring 1 .35 A fuse .
[F3] for PXC200: self-restoring 1 .35 A fuse .
[+, U5, U6, U7, U8, -] CN6 connector for negative program-
mable open collector outputs protected by 100 ohm resis-
S
tor (ON=0 V DC, OFF=NA) . (ONLY PXC200)
PXC96