System Test

System Test
1 .
Go into the Technical Menu .
(▲)/(▼)
2 .
With
select
SYSTEM
(▲)/(▼)
3 .
With
select
TEST
(▲)/(▼)
4 .
With
select the parts of the system that you want to
check and press (*) .
(#)
5 .
Press
to quit and go back to the previous menus .
Connecting PC – Control unit
Once the components of the system have been defined (previous
sections), you can move on to programming the control unit from
either a keypad or the PC via direct or remote connection .

Local programming via USB

Opening control unit
When the control unit is opened by removing the cover, the system
goes into alarm mode .
To avoid this, you must:
1 .
Go into the Technical Menu .
2 .
Open the control unit by undoing the relevant screws .
3 .
To prevent alarms being triggered at the end of programming
because of possible programming errors, we recommend put-
ting the control unit into maintenance mode . See also "START-
UP" section .
4 .
Put the control unit into maintenance mode, setting Dip 1 to
ON .
Connecting PC to control unit
1 .
Install the control unit programming software on your own PC .
2 .
Connect the control unit to the PC using a type A-B USB cable .
Settings on PC (to be done only once)
and press (*) .
and press (*) .
SYSTEM
SYSTEM 02
▼ ▲
*
TEST
▼ ▲
SYSTEM
*
INPUTS TEST
*=LAUNCH TEST
INPUTS CLOSED
#=ESC
C.U. TAMP. TEST
*=LAUNCH TEST
TAMPER CLOSED
#=ESC
C.U. BATT. TEST
*=LAUNCH TEST
C.U. BATTERY OK
#=ESC
1 .
On the PC set the password to access the control unit (the
same as the Technical Code 222222 which is factory-set) .
2 .
Select the COM communication serial port .
Set the programming mode on the Control unit (to be done only
once), choosing from
programming with control unit off
programming with control unit off after entering user
code
To set the desired mode, you must:
1 .
Go into the Technical Menu .
(
)/(
)
and press (*) .
2 .
With
select
CODES
(
)/(
)
3 .
With
select
INSTALLER
(
)/(
)
4 .
With
select
PROGRAM. FROM PC
(+)/(–)
5 .
With
change the parameter:
, direct programming without entering user
WITH CTL-U. OFF
code with control unit off .
, programming only after entering user code
AFTER USER CODE
with control unit off .
(#)
6 .
Press
to quit and go back to the previous menus .
CODES 16
*
TECHNICAL CODE
INSTALLER
*
PROGRAM. FROM PC
WITH CTL-U. OFF
BATTERY TEST XX
*=LAUNCH TEST
BATTERY ALXX OK
#=ESC
SIRENS TEST
*=LAUNCH TEST
ALARM OUTPUTS
-OFF- *=ON #=ESC
ALARM OUTPUTS
>ON< *=OFF #=ESC
and press (*) .