Control Unit Installation; General Characteristics - CAME PXC48 Manuel Installateur

Masquer les pouces Voir aussi pour PXC48:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Control unit installation

CHARACTERISTICS

GENERAL CHARACTERISTICS

Power supply voltage [V AC]
Power supply frequency [Hz]
Power supply [A]
Transformer [VA]
Board power draw (excluding battery recharging) [mA]
Battery [Ah]
Operating temperature [°C]
Relative humidity [%]
Maximum safety level
Environmental class
Insulation class
Dimensions (HxWxD)
IP Rating
Weight (without battery) [Kg]
Areas
Scenarios
Total number of inputs
Wired inputs
Radio inputs
Inputs in control unit
Wired inputs expansions on BUS
Type of inputs in control unit
Type of inputs on BUS
On-board relay outputs
Total number of programmable outputs
Programmable control unit outputs
Programmable BUS outputs
Outputs expansion modules on BUS
Radio concentrator modules on BUS
Readers
Keypads
Touch screen
Transponder keyfobs
Installer codes
User codes
Remote controls
Programmer
Events
BUS 485
PSTN phone dialler
GSM phone dialler
Voice synthesis
Phone numbers
CONTACT-ID
Power supply units on BUS
Reprogramming of control unit FW
LAN
USB communication port
SMS control
VOICE control
Programming and Remote Assistance LAN
Programming and Remote Assistance PSTN
Programming and Remote Assistance GSM
RTC + back-up battery
* The control unit manages 1 expansion module in the control unit + 1 remote expansion module for 8 inputs on the bus, or 2 remote
expansion modules for 8 inputs on the bus .
** The control unit manages 1 expansion module in the control unit + 4 remote expansion modules for 8 inputs on the bus, or 5 remote
expansion modules for 8 inputs on the bus .
*** The control unit manages 1 expansion module in the control unit + 14 remote expansion modules for 8 inputs on the bus, or 15 remote
expansion modules for 8 inputs on the bus .
PXC48
230 (- 15% + 10%)
1
20
70
7 .2
-10 ÷+ 40
25% - 75% without condensation
2
II
305x215x70
2 .70
4
32
48
24
24
8
2 (16)*
NC, NA, SB, DB, CI
NC, NA, SB, DB, CI
NC, NA, SB, DB, CI
NC, NA, SB, DB, CI
1
20
4
16
2
2
4
4
Yes
20 (99 with PXV256)
50 (999 with PXV256)
1
20 (99 with PXV256)
50 (999 with PXV256)
8
Daily/Weekly
250 (999 with PXV256)
999 (9999 with PXV256)
1
Yes
Optional
Optional
8
Yes
No
Yes
Optional
Yes
Yes (with GSM)
Yes (with PXVxxx)
Yes (with PXVxxx)
Yes (with LAN)
Yes
Yes (with GSM)
Yes
PXC96
50/60
1 .5
38
70
7 .2 or 15
-10 ÷+ 40
-10 ÷+ 40
2
II
I
405x295x90
490x360x90
30
4 .50
8
32
96
48
48
8
5 (40)**
15 (120)***
NC, NA, SB, DB, CI
NC, NA, SB, DB, CI
1
44
4
40
5
8
8
8
Yes
50 (999 with PXV256)
1
50 (999 with PXV256)
32
Daily/Weekly
Daily/Weekly
999 (9999 with PXV256)
1
Yes
Optional
Optional
16
Yes
8
Yes
Optional
Yes
Yes (with GSM)
Yes (with GSM)
Yes (with PXVxxx)
Yes (with LAN)
Yes (with LAN)
Yes
Yes (with GSM)
Yes (with GSM)
Yes
PXC200
2 .5
52
71
15
2
II
5 .95
16
32
200
128
72
8
2
128
8
120
15
16
16
16
Yes
1
32
2
Yes
Optional
Optional
16
Yes
16
Yes
Optional
Yes
Yes
Yes

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pxc96Pxc200

Table des Matières