Maximum communication performance is guaranteed
with the use of the cable as in the specs (PXC75) . The maximum
communication speed between the peripherals is 115200 baud . If
the cable indicated is not used, or problems arise with installation,
the transmission speed at the control unit may be reduced (38400,
9600, 4800 and 2400 baud) . The speed of the peripherals will be
set automatically .

Cabling inputs

Balances are achieved with 4 .7 kohm resistors at 5% .
Yellow
Purple
Red
Gold
NORMALLY OPEN (NA)
NORMALLY CLOSED (NC)
SINGLE BALANCE (SB)
DOUBLE BALANCE (DB)
PULSE OR INERTIA COUNTER (CI)
4
7
x100
5%
4,7 KOHM
4,7 KOHM
4,7 KOHM
4,7 KOHM
4,7 KOHM
+
-
TC
TAMPER ALARM
4,7 KOHM
4,7 KOHM
4,7 KOHM
+
-
TC
TAMPER ALARM
+
-
TC
TAMPER ALARM
4,7 KOHM
+
-
TC
TAMPER ALARM
+
-
TC
TAMPER ALARM
DOUBLE BALANCE SENSOR (DB)
DOUBLE BALANCE SENSOR (DB) WITH MICROWAVE BLOCK WHEN
CONTROL UNIT OFF (TC)
Output U1 yields a positive with output on (ON=13 .8V DC) . Output
U1 is factory set as TC (output on when system off and off during
exit time and when at least one area is on) .
4,7 KOHM
4,7 KOHM
+
-
TC
TAMPER ALARM
+
-
TC
TAMPER ALARM
+
-
TC
TAMPER ALARM
+
-
TC
TAMPER ALARM