Main Components Of The Control Unit; Description Of Circuit Board - CAME PXC48 Manuel Installateur

Masquer les pouces Voir aussi pour PXC48:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Main components of the control unit

PXC48
A
G
B
E
F
D
C
1 Terminals for connecting 230 V AC grid .
2 Faston / Terminal for connecting to earth
3 Cable for connecting cover to earth
4 47 kohm temperature sensor (optional) PXSTB
E Cables for connecting battery .
F Control unit tamper
G Network fuse .
For PXC48: no fuse, a thermal protector to 130° is included in the transformer .
For PXC96: no fuse, a thermal protector to 130° is included in the transformer .
For PXC200: glass T fuse, 500 mA .

Description of circuit board

PXC48-PXC96
L
K
N
H
J
M
I
A
RS-485 bus terminals for connecting keypads, remote
modules and readers .
[+,-] bus power supply .
[A,B] data .
1
[F6] for PXC48: no fuse .
[F6] for PXC96: self-restoring 1 .35 A fuse .
[F6] for PXC200: self-restoring 1 .35 A fuse .
Terminals for control unit inputs, can be types NA, NC, SB,
DB, CI .
[+,-] power supply .
[1,2,3,4] inputs . The reference is negative .
2
[F3] for PXC48: no fuse .
[F3] for PXC96: self-restoring 1 .35 A fuse .
[F3] for PXC200: self-restoring 1 .35 A fuse .
G
E
D
Be careful, live parts
Respect the polarity (red = +, black = -)
G
F
E
B
C
D
PXC96
A
B
C
F
L
M
N
J
O
Q
P
A
Terminals for control unit outputs.
[AUX +, -] [power supply available via self-restoring fuse
protected output F5 .
[U1] programmable positive output protected by 100 ohm
resistor (ON=13 .8 V DC, OFF=NA) .
[U2] for the PXC200 it's a relay C-NA output, for the others
it's a negative programmable open collector output pro-
tected by 100 ohm resistor (ON=0 V DC, OFF=NA) .
[U3, U4] negative programmable open collector outputs
C
protected by 100 ohm resistor (ON=0 V DC, OFF=NA) .
[NO, C, NC] general alarm relay with clean contacts (one
only for PXC48 and PXC96) .
[F5] for PXC48: no fuse .
[F5] for PXC96: self-restoring 1 .35 A fuse .
[F5] for PXC200: self-restoring 1 .35 A fuse .
A short circuit with open collector output active for a
long time may lead to breakage of the protective resistor
PXC200
B
A
G
C
E
D
PXC200
K
G
H
I
R
E
S
B
C
F
F
D

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pxc96Pxc200

Table des Matières