HOW TO USE YOUR SPA
of the filter cycle.)
If the Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when
Filter Cycle 2 is programmed to begin.
The Meaning of Filter Cycles
1. The heating pump always runs during the filter cycle*
2. In Rest Mode, heating only occurs during the filter cycle
3. Purges happen at the start of each filter cycle
* For example, if your spa is set up for 24/hour circulation except for shutting off when the water
temperature is 3˚F/1.3˚C above the set temperature, that shutoff does not occur during filter
cycles.
3.4.4. ERROR MESSAGES - TP600-TP800 AND TOUCH CONTROL PANELS
Message
Meaning
Water Temperature
is Unknown
Possible freezing
A potential freeze condition has been
detected, or the Aux Freeze Switch has
condition
closed.
The water is too
The system has detected a spa water
temp of 110°F (43.3°C) or more, and spa
hot – M029
functions are disabled.
The water level is
This message can only appear on a system
that uses a water level sensor. It appears
too low
whenever the water level get too low (or
the water level sensor is disconnected)
The water flow is
There may not be enough water flow
through the heater to carry the heat away
low – M016
from the heating element.
The water flow has
There is not enough water flow through
the heater to carry the heat away from
failed – M017
the heating element and the heater has
been disabled.
The heater may be
Possible dry heater, or not enough water
in the heater to start it. The spa is shut
dry – M028
down for 15 min.
The heater is dry –
There is not enough water in the heater to
start it. The spa is shut down.
M027
The heater is too
One of the water temp sensors has
detected 118°f (47.8°C) in the heater and
hot – M030
the spa is shut down.
Flow-Related
Checks
Sensors are out of
The temperature sensors MAY be out of
sync by 3°F.
sync – M015
Action required
After the pump has been running for 1 minute, the
temperature will be displayed.
All water devices are activated. In some cases, pumps
may turn on and off and the heater may operate
during Freeze Protection.
This is an operational message, not an error
indication.
System will auto reset when the spa water temp
is below 108°F (42.2°C). Check for extended pump
operation or high ambient temp.
Automatically disappears when the water level is
adequate. Pumps and the heater turn OFF when this
message appears.
Heater start up will begin again after about 1 min.
See: **.
See: **.
See: **.
After the problem has been resolved, you must reset
the message to restart heater start up.
See: **.
You must reset the message when water is below
108°f (42.2°C).
See: **.
Check for low water level, suction flow restrictions,
closed valves, trapped air, too many closed jets and
pump prime.
Call for Service if this message does not disappear
within a few minutes.