HOW TO USE YOUR SPA
TP600 Control Panels MODE READY and REST / READY IN REST MODE
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that
performs this function is known as the "heater pump." The heater pump can be either a 2-Speed
Pump 1 or a circulation pump. If the heater pump is a 2-Speed Pump 1, READY Mode will circulate
water every 1/2 hour, using Pump 1 Low, in order to maintain a constant water temperature, heat
as needed, and refresh the temperature display. This is known as "polling."
REST Mode will only allow heating during programmed filter cycles. Since polling does not occur,
the temperature display may not show a current temperature until the heater pump has been
running for a minute or two.
If the spa is configured for 24HR circulation, the heater pump generally runs continuously. Since
the heater pump is always running, the spa will maintain set temperature and heat as needed in
Ready Mode, without polling.
In Rest Mode, the spa will only heat to set temperature during programmed filter times, even
though the water is being filtered constantly when in Circulation Mode.
Main Screen
To next item in
Main Menu
Toggle between READY and REST
If not toggled
Pressing Light when the display is toggled will go to Main Screen.
READY Mode will allow the spa to Poll and determine a need for heat. The panel will maintain a "current" temperature display.
REST Mode will not Poll and will only heat during filter cycles. The panel will not display a current temperature at all times.
Main Screen
1 Hour
The Main Screen will display RUN PUMP FOR TEMP if the filtration pump has not run for over 1 hour.
The Main Screen will display normally during Filter Cycles or when the spa is in use.
If the filtration pump has been off for an hour or more, when any function button, EXCEPT Light, is pressed on the panel,
the pump used in conjuncton with the heater will run so that temperature can be sensed and displayed.
Ready-in-Rest Mode
READY/REST appears in the display if the spa is in Rest Mode and Jet 1 is pressed. It is assumed
that the spa is being used and will heat to set temperature. While Pump 1 High can be turned on
and off, Pump 1 Low will run until set temperature is reached, or 1 hour has passed. After 1 hour,
the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and
changing the Mode.
Main Screen
Main Screen
J
12
Spa for private use - Operating instructions
While the Temperature is
still flashing, press Light
repeatedly until MODE
appears in the LCD.
Main Screen
To Set
*****
Waiting
Several Seconds
Reverts to Original Setting
KEY
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message -
every 1/2 second
A temperature button, used for "Action"
Light or dedicated "Choose" button, depending
on control panel configuration
Waiting time that keeps the last change
to a menu item.
Waiting time (depends on menu item) that
*****
reverts to original setting and ignores any
change to that menu item.