HOW TO USE YOUR SPA
Sensors are out
of sync -- Call for
service – M026
Sensor A Fault,
Senor B Fault –
Sensor A: M031,
Sensor B: M032
Communications
error
Test software
installed
Program memory
failure – M022
The settings
have been reset
(Persistent Memory
Error) – M021
The clock has failed
– M020
Configuration error
(Spa will not Start
Up)
A pump may be
stuck on – M034
Hot fault – M035
** Some messages can be reset from the panel. Messages that can be reset will appear with a Clear
Icon at the bottom of the Message Screen. Press the Clear Icon text to reset the message.
REMINDER MESSAGES
General maintenance helps: Reminder Messages can be suppressed by using the Reminders
Screen. Reminder Messages can be chosen individually by the Manufacturer.
Check the pH : May appear on a regular schedule, i.e. every 7 days. Check pH with a test kit and
adjust pH with the appropriate chemicals.
Check the sanitizer: May appear on a regular schedule, i.e. every 7 days. Check sanitizer level
and other water chemistry with a test kit and adjust with the appropriate chemicals.
Clean the filter: May appear on a regular schedule, i.e. every 30 days. Clean the filter media as
instructed by the manufacturer.
22
Spa for private use - Operating instructions
The temperature sensors ARE out of sync.
A temperature sensor or sensor circuit has
failed.
The control panel is not receiving
communication from the System.
The Control System is operating with test
software.
At Power-Up, the system has failed the
Program Checksum Test.
Water may be overheated.
A Pump Appears to have been Stuck
ON when spa was last powered POWER
DOWN THE SPA.
The fault above has been established for at least 1
hour.
Call for Service.
See: **.
If the problem persists, contact your vendor or a
service engineer.
See: **.
If the problem persists, contact your vendor or a
service engineer.
If the problem persists, contact your vendor or a
service engineer.
This indicates a problem with the firmware (operation
program) and requires a service call.
See: **.
Contact your service organization if this message
appears on more than one power-up.
See: **.
If the problem persists, contact your vendor or a
service engineer.
See: **.
If the problem persists, contact your vendor or a
service engineer.
POWER DOWN THE SPA. DO NOT ENTER THE WATER.
Contact your dealer or service organization.
DO NOT ENTER THE WATER.
If the problem persists, contact your vendor or a
service engineer.