Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Intended Use

Rating Plates

The rating plates include the following information:
• Identification of input and output ranges
• The test voltages
• Measuring ranges that can be adjusted using S1 and S2 rotary switches
(except fixed-range models)
• Information on power supply connection
Note: The specifications on the transducer's rating plates take precedence.
P51100 Rating Plate and Measuring Ranges
High-Voltage Transducer
Type P51100K11-M1M/11
No.
0000000
14163 Berlin
nnnnn / 0000000 / jjww
Input
(End of Scale)
Switch
S1
Switch
30
mV
0
50
mV
1
60
mV
2
90
mV
3
100
mV
4
100
*
)
Shunt Monitoring
Calibrated selection of
measuring range and
shunt monitoring using
S1 rotary switch
ProLine
ES01
Made in Germany
01
Output
S1
*
mV )
30
5
Switch
*
)
50
mV
6
±20
*
)
60
4 to 20
mV
7
*
)
90
mV
8
*
)
mV
9
±10
Power
24 to 230 V AC (50/60 Hz) / DC
DC: -30 % / +10 %, 2.5 W
AC: -20 % / +10 %,
Isolation
Input - Output/Supply
Routine Test Output - Supply
Operating Temperature
(Input Bipolar)
10Hz
14kHz
S2
mA
0
4
1
mA
5
±5
V
2
6
V
3
7
Calibrated output selection
using S2 rotary switch
U L
®
LISTED
6 VA
16
4
40 to +85 °C
Output
(Input Unipolar)
10Hz
Switch
S2
0 to 20
mA
0
4 to 20
8
mA
0 to
5
V
2
0 to
10
V
3
51
Example
kV
kV
14kHz
4
9
6
7

Publicité

Table des Matières
loading

Table des Matières