9 Be sure to ground (earth) the
generator.
NOTE:
Use ground (earth) lead of suffi-
cient current capacity.
743-026
1 Lead diameter
Ground (earth) Lead
Diameter:
0.12 mm (0.005 in)/ampere
EX:
10 Ampere¡1.2mm
(0.05 in)
G-385

CONNECTION NOTES

9 Do not connect the generator to
a commercial power outlet.
9 Do not connect the generator in
parallel with any other genera-
tor.
1 Correct
2 Incorrect
w
Before the generator can be con-
nected to a building's electrical
system, a licensed electrician
must install an isolation (trans-
fer) switch in the building's main
fuse box. The switch is the con-
nection point for generator
power and allows selection of
generator or main line power to
the building. This will prevent the
743-027
generator from charging the
main power line (backfeeding)
when the main power supply has
failed or has been turned off for
– 13 –
9 务必接好地线。
注意:
确保地线能承载足够的电流。
1 地线的直径
地线
直径:
0.12mm(0.005in)/A
例:
10A → 1.2mm
(0.05in)
G-385
接线注意事项
9 切勿将本发电机与市电连接。
9 切勿将本发电机与其他发电机并
联使用。
1 正确
2 不正确
q 警告
在将发电机与建筑物的电力系统
连接之前,经认可的电气师必定会在
建筑物的主保险箱中安装一个断开
(传输)开关。 此开关是发电机与电力
系统的连接点,可以选择是使用发电
机还是使用干线电源为建筑物供电。
当干线电源有问题,或为修理供电线
路而切断干线电源时,这可以防止发
电机为干线供电(反馈) 。 电源反馈会
使维修线路的人员触电死亡或受伤。