wood...) on the table undemeath the workpiece. This
wiII prevent splitering or making a heavy burr on the
underside of the workpieces as the drill bit breaks
through. To keep the back up material from spinning
out of control it must contact the left side of the col-
umn as illustrated.
Warning:
To prevent the work piece or the backup material
from being torn from your hand while drilling, position
them to the left side of the column. If the work piece
or the backup material are not long enough to reach
the column, clamp them to the table. Failure to do
this could result in personal injury.
Note: For small pieces that cannot be clamped to the
table, use a drill press vice.
The vice must be clamp or bolt to the table to avoid
injury from spinning work and vise or tool breakage.
Drilling (Fig. 1)
1
Switch on the device.
2
Turn one of the feed handles (10) anticlockwise.
The drill chuck (4) comes down.
3
Drill the workpiece with the proper feed rate and
4
the desired depth.
Please note that chip breaking might be required to
5
reach the desired drill depth.
6
Slowly return the tool to the stop position.

Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been im-
properly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
All manuals and user guides at all-guides.com
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
The mains voltage must be 230 V~
Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
Cleaning and Servicing
Pull the mains plug before any adjustments,
maintenance or repair.
m Have any work on the device that is not de-
scribed in this instruction guide performed by
a professional. Only use original parts. Allow
the device to cool off before any maintenance
or cleaning is undertaken. There is a risk of burn-
ing!
Always check the device before using it for obvi-
ous defects such as loose, worn or damaged parts,
correct the positioning of screws or other parts. Ex-
change the damaged parts.
Cleaning
Do not use any cleaning agents or solvents. Chemi-
cal substances can etch the plastic parts of the de-
vice. Never clean the device under running water.
• Thoroughly clean the device after every use.
• Clean the ventilation openings and the surface of
the device with a soft brush or cloth.
• Remove chips, dust and dirt with a vacuum clean-
er if necessary.
• Lubricate moving parts regularly.
• Do not allow lubricants to come into contact with
switches, V-belts, pulleys and drill lifting arms.
Tightening pulleys (Fig. 1 / 9)
Vibrations that occur while the machine is running
may cause the pulleys (F, G, H) coming loose.
If necessary, tighten the pulleys with an Allen wrench
(19).
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Carbon brushes, V-belt, batteries, drill
bit
* Not necessarily included in the scope of delivery!