SELECTION OF ADHESIVE WEIGHTS APPLICATION
The machine makes it possible for the operator to select where the adhesive weight should be ap-
plied based on his needs.
To select this configuration, proceed as described below:
- Press the
button to access the programme menu
- use the
- Select the FN programme icon
- The message ALU will appear on the left display, whereas the message LAS will appear on the right
display that indicates the selection of the adhesive weight application enabled on the machine;
- press the
in H12 or CLP.
- press
to confirm the selection made and exit the function.
- To apply the balancing weights refer to the following table:
TYPE OF WEIGHT TO
BE APPLIED
Traditional clip
Adhesive
Adhesive
Adhesive
When the LAS configuration is enabled, the message ON is displayed in the status line of the LCD display.
Before starting a balancing operation, the following steps must be followed:
- fit the wheel on the hub using the most suitable flange;
- lock the wheel so that no movement is possible during the wheel spin and braking phases;
- remove any counterweight, pebble, dirt or other foreign body;
- correctly set the wheel's geometric data as described in the "WHEEL DATA ENTRY" chapter.
Proceed as follows to balance a wheel in dynamic mode:
- correctly set the wheel's geometric data as described in the "WHEEL DATA ENTRY" chapter.
- the message DYNAMIC will be displayed in the status line on the LCD display.
This programme is automatically launched when the machine is switched on.
- Set the wheel's geometric data.
- Spin the wheel by lowering the guard.
58
POSITION
buttons to move the cursor
button to change the machine configuration; this configuration can be changed
CONFIGURATION
SELECTED
H12
LAS
CLP

BALANCING PROGRAMMES

Dynamic balancing (standard)
WEIGHT APPLICATION POSITION
Always 12 o'clock
12 o'clock in all balancing programmes
6 o'clock using the LASER line in all balancing
programmes
using the weight-holder terminal in the ALU1P/
ALU2P balancing programmes, whereas the 12
o'clock position is used in the statistical ALU
programmes
EM 9550 - Operator's manual