Possible cause
1. The thermostat is set to too low a tempera-
ture.
2. The electrical connection between the pcb
and the motor is interrupted.
Remedy
1. Set the thermostat knob to a higher tempera-
ture.
2. Check all electrical connections.
Problem
The LED fl ashes and "E3" appears in the display.
Possible cause
The thermostat switch is defective.
Remedy
Replace the thermostat switch.
Problem
Poor combustion and / or formation of soot.
Possible cause
1. Flames emerge from the front of the housing.
2. Too low a heat output.
3. Poor fuel quality.
4. Generally poor maintenance.
Remedy
1. Reduce the pump pressure.
2. Increase the pump pressure.
3. Check whether old or dirty fuel is being used.
4. Have the equipment serviced by specialized
personnel.
Problem
The heater does not switch and on the LED does
not light up.
Possible cause
1. The equipment is overheated and therefore
the safety temperature limiter has responded.
2. No mains voltage.
3. Defective miniature fuses.
4. Connection between the thermostat and the
pcb has been interrupted.
Remedy
1. Set the ON/OFF switch to OFF (0) and allow
the heater to cool for at least 10 minutes.
Then set the On/Off switch back to ON (I).
2. Check the socket-outlet, the power cable and
the extension cable.
3. Check the miniature fuse and replace it if
Anl_DHG_360_SPK7.indb 29
Anl_DHG_360_SPK7.indb 29
GB
necessary.
4. Check all electrical connections.