22 Dt / 30 Dt / 40 Dt
Ventilation
Fresh air ventilation activates by pressing the ventilation switch (7) continuously at
least 2 seconds. Ventilation is indicated with the green ventilation light (8). Venti-
lation is deactivated by pressing the ventilation switch (7) continuously at least 2
seconds. The green ventilation light (8) will shut off.
When pressing the ventilation switch (7) continuously at least 2 seconds, while
heating is on, the heater will shut off and after the aftercooling mode, the heater
goes to ventilation mode.
The ventilation can be adjusted smoothly. The thermostat control deactivates after
switching to ventilation mode. When pressing the heating switch (3) at least 2 sec-
onds while the ventilation is on, the heater will start and go to heating mode.
Note ! when adjusting the ventilation effect the change of rotation speed of the
ventilation motor will take place slowly after the knob is turned.
Shutdown
You can shut down the heater by pressing the heating switch (3) continuously for at
least 2 seconds. The yellow heating indicator light (9) will go out immediately. The
red combustion indicator light (1) will continue to blink for about five minutes, while
the device is cooling down. You cannot restart the device until the combustion light
has stopped blinking.
Remote control
The heater can be controlled manually with an accessory, which can be purchased
separately.
If the device is started using the remote control, the orange indicator light (5) on the
control panel will blink at 10-second intervals.
The sun-switch is not enabled in this mode.
The ventilation cannot be used with the remote controller.
Signal lights
Colour
Blink interval
Yellow
Green
Yellow
Green
Red
Red
Orange
Orange
Orange
10 s
Orange
Operation
10 s
10 s
10 s
30 s
- 86 -
Function
Heating on
Ventilation on
Air boost
Combustion indicator when the com-
bustion has begun normally
Aftercooling
Thermostat control, the set tempera-
ture exceeds the set value > power is
increasing
Thermostat control, the set temperature
is lower than the set value > power is
decreasing
Device in remote control mode
Sun switch has shut down the device
en