D10021B
22 Dt / 30 Dt / 40 Dt
Installation
Electrical connections
Things to note about the connections
The device uses 12 V (nominal) direct current voltage. To minimize current losses,
make the power cable as short as possible and avoid joining. The cross-sectional
area of the cable is dependent on the length of the power cord. The cross-sectional
area of the cable must be consistent all the way from the stove to the battery. The
maximum length of the power cord is 10 m, based on 6 AWG cable.
The cross-sectional area of the cable
Total length of the power cord (m)
0 - 4
4 - 6
6 - 10
If a thicker cable is required, make a separate joint in the power cord. See picture
on the next page.
Main switch
A main switch must be installed on the device's "positive (Red)" cord. Always cut
the power at the main switch (after cooling has completed), if the device is going to
be left unused for a long period of time.
Recommended main switch should be 20 V DC / 20 A DC minimum.
Never use the main switch to cut the power before the cooling phase
is completed.
Cross-sectional area of the cable in square mm
- 64 -
en
(US Gauge)
4 (11 or 10 AWG)
6 (9 or 8 AWG)
10 (7 or 6 AWG)
490526C