Installation instructions for Solenoid valve 30012 (accessory)
The solenoid valve 30012 prevents the tank from emptying in case the fuel line
breaks.
The fuel filter should be installed before the solenoid valve.
1
6
Our recommendations in the fol-
lowing
installation scenarios:
1. Fuel level is below the heater/stove.
Picture 1.
Recommended installation scenario
No special accessories required
2. Fuel level may temporarily rise above
the heater/stove (e.g. in the fuel tank
filler pipe or when the boat tilts).
Picture 2.
No special accessories required
3. Fuel level is above the heater/stove.
Picture 3.
Non-recommended installation sce-
nario
Solenoid valve 30012 must be in-
stalled in the fuel hose near the tank.
If the fuel level in the tank is above the device, a solenoid valve
30012 must be installed in the fuel line immediately after the tank
lead-through.