g) Use with an external DMX controller
Each DMX device in a DMX chain requires a so-called DMX starting address to be clearly identified by the
controller. This DMX starting address specifies the first DMX channel to which the effect light re-sponds.
The remaining control channels come after this first DMX channel (DMX starting address).
The effect light requires up to 9 DMX channels.
Setting the DMX start address and the DMX mode
• Select automatic mode again (display DMX-mode - A001-A512) with the button MODE.
• Select the desired start address A001-A512 with the UP and DOWN buttons.
• Push the ENTER button.
• Select DMX mode (2Ch or 9Ch) with the buttons UP and DOWN.
The display automatically switches back to address settings after a few seconds.
The address display flashes if no DMX or master/slave signal is pending at the DMX IN socket.
The following tables provide information about the effects of the settings on the individual DMX channels.