1 1 8 8 . . R R e e d d u u c c i i n n g g t t h h e e r r u u n n n n i i n n g g s s p p e e e e d d
By setting the dip switch 6 to ON, the motor only runs at half speed. At half
speed, the centrifugal mass of a door is lower and thus, among other things,
the forces required at the closing edge can be better maintained. After switch-
ing the speed, the control unit must be reset so that the running times and
forces can be taught in again.
1 1 9 9 . . T T a a r r g g e e t t e e d d O O P P E E N N / / C C L L O O S S E E
The two inputs Pulse / CLOSE and Partial opening / OPEN can be switched to
the Targeted OPEN / CLOSE function with and without panic function using dip
switches 7 and 8. Switching from impulse / partial opening function to targeted
OPEN / CLOSE has no influence on the function of the radio channels.
If one of the OPEN or CLOSE inputs is actuated during a motor run for targeted
OPEN / CLOSE with panic function, the motor stops (soft stop). For targeted
OPEN / CLOSE without panic function, actuation of the input for the current
direction has no effect during a motor run. When the input for the opposite
direction is actuated, the running direction is changed.
If both inputs are actuated simultaneously, the motor always stops immediate-
ly without a soft stop.
IMPULSE – Function:
Targeted OPEN / CLOSE without panic
function
Targeted OPEN / CLOSE with panic func-
tion
2 2 0 0 . . D D e e a a d d - - m m a a n n m m o o d d e e
To activate the dead man's mode, switch dip switches 7 and 8 to ON.
The motor will then run in the desired direction only as long as the input is ac-
tuated. Radio operation is not possible during dead man operation.
S1.7 =
OFF
S1.7 =
ON
S1.7 =
OFF
22
S1.8 =
OFF
S1.8 =
OFF
S1.8 =
ON