BelFox 47-21-0 Instructions D'installation page 51

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Note:
Zu S1.3:
In the case of automatic closing, there is a 5 second pre-
warning. If the prewarning time is not activated (S1.5 = off),
the prewarning is also given via a flashing light output.
Zu S1.5:
A self-flashing warning light is required.
Zu S1.7/S1.8:
In dead-man mode, the automatic closing function is not ef-
fective. Safety inputs must be provided with be provided
with bridges.
13.2. Safety switch (DIP switch) 1+2
S2.1
Entrance LS / SE1
Main closing edge
S2.2
Entrance LS / SE2
Secondary closing
edge
1 1 4 4 . . C C h h a a n n g g e e s s o o f f t t s s t t o o p p
The running distance of the soft stop can be varied with DIP switches 1 and 2:
1 OFF
1 ON
1 OFF
1 ON
ON =
8k2 Safety edge
OFF =
Light barrier
ON =
8k2 Safety edge
OFF =
Light barrier
2 OFF
Normal soft stop
2 OFF
Short soft stop
2 ON
Long soft stop
2 ON
soft stop only in "OPEN" direction
19
1
2

Publicité

Table des Matières
loading

Produits Connexes pour BelFox 47-21-0

Table des Matières