1 1 5 5 . . A A u u t t o o m m a a t t i i c c c c l l o o s s i i n n g g
In the area of the door system, damage or injuries can occur during door
movements. The gate wing can collide with persons who are in the movement
area of the gate and (seriously) injure them. Limbs can be caught by the gate
and taken along. There is a risk that limbs that get between the sliding gate
and fixed parts of the system could be cut off.
SAFETY INSTRUCTION FOR DANGER AVOIDANCE
x Children and animals must be kept away from the gate system when the
gate is moving. Children are not allowed to play at the gate system.
x Make sure that neither persons nor objects are in the path of the gate.
x The free space between the gate wing and the floor must be selected in
such a way that there is no danger of the feet being carried along.
x If possible, the door should only be operated when there is visual con-
tact with the movement range of the door.
x Monitor the door movement until the door has reached its end position.
x During opening and closing of the gate, the working area of the gate sys-
tem must not be entered or passed through!
x Do not stand still in the opened door system!
x
If possible, install an emergency stop command device in order to be
able to trigger an immediate stop in an emergency
The automatic closing mode can be activated with dip switch 3. In this operat-
ing mode, the gate can only be opened with a pushbutton, key switch, etc., and
the gate is always closed automatically. This automatic mode requires at least
the use of a light barrier. To program the hold-open time, move the gate from
the CLOSED position to the OPEN position, wait for the desired hold-open time
and then move dip switch 3 to the ON position.
This programs the hold-open time, the maximum hold-open time is 3 minutes.
The automatic closing function also works together with the partial opening
program. If the door is in the OPEN end position and an operating impulse is
given, the hold-open time runs from the beginning.
WARNING
Risk of injury during door movement!