Les langues disponibles

6 6 . . T T e e r r m m i i n n a a l l b b l l o o c c k k s s
An extra terminal strip was installed in the control box for easy wiring.
1
mains L
2
mains N
3
mains PE
4
warning light 230 V AC
5
warning light 230 V AC
6
3-minutes-light 230 V
7
3-minutes-light 230 V
8
Touch buttonmpulse/Closed
9
touch button - shared
10
touch button partial opening
11
stop
12
stop
13
main closing edge
14
main closing edge
15
secondary closing edge
16
secondary closing edge
17
24 V AC max. 0,5 A
18
24 V AC max. 0,5 A
7 7 . . l l u u m m i i n n o o u u s s d d i i o o d d e e s s
LED Mains green: Operating voltage is present
LED radio yellow: radio - reception / learning / deleting
LED Error red: Display error / self-test
8 8 . . B B u u t t t t o o n n
radio – button:
learn radio / learn partial opening / delete radio /
reset control
Pulse - button:
Pulse operation / Reset control system
Terminal 8, 9, 10; function depending on posi-
tion of dip-switch 7
ON
Æ Æ targeted OPEN / CLOSE
OFF
Æ Æ touch button
11, 12
Terminal
13, 14
15, 16
13
Unused inputs must
be bridged. Connec-
tions according to
points 21.1, 22 of
these instructions