as when a vheicle, trips the sensor while the gate is still moving, and
• One or more non-contact sensor shall be located where the risk of
entrapment or obstruction exist, such as the perimeter reachable by
a moving gate or barrier.
FOR GATE OPERATOR PROVIDED WITH CONTACT DETECTION
(RUBBER EDGE OR SIMILAR):
• On or more contact sensor shall be located at the pinch point of a
vehicular vertical pivot gate.
• A hardwired contact sensor shall be located and its wiring arranged
so that the communication between the sensor and the gate operator
is not subjected to mechanical damage.
• A wireless contact sensor such as one that transimts radio frequency
(RF) signals the gate operator for entrapment protection functions
shall be located where the transimission of the signals are not
obscrtucted or impeded y building structure, natural landscaping
or similar obstruction. A wireless contact sensor shall function under
the intended end-use conditions.
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS: to reduce the risk of injury or death:
• Read and follow all instructions.
• Never let children operate or play with gate control. Keep the remote
control away from children.
• Always keep people and objects away from the gate. NO ONE SHOULD
CROSS THE PATH OF THE MOVING GATE.
• Test the gate operator montly. The gate MUST reverse on contact with
a rigid object activates the non-contact sensor. After adjusting the
force or the limit of travel, reset the gate operator. Failure to adjust
and retest the gate operator properly can increase the risk of injury
or death.
• Use the emergency realease only when the gate is not moving.
• KEEP GATES PROPERLY MAINTAINED. Read the owners manual.
Have a qualified service person make repairs to gate hardware.
• The entrance is for veichles only. Pedestrians must use separate
entrance.
• Save these instructions.
4) ACCESSORIES
- CPS Bearing foundation case (provided for automation).
- CID Non-bearing foundation case.
- BSC Slide arm (for mounting to one side of the hinge-pivot).
5) TECHNICAL SPECIFICATIONS
Single-phase power supply ........................................120V~ ±10% 50/60 Hz
Motor revolutions ................................................................................. 2800 min
Output shaft revolutions ...................................................................See Table 1
Absorbed power .............................................................................................250 W
Capacitor ............................................................................................................ 6.3 µF
Absorbed current ............................................................................................. 1.4 A
Max torque ...................................................... 400 Nm.....................295.02 lbf/ft
Pressure ......................................max 3MPa (30 bar)..........max 62656.3 lb/ft
Pump capacity .......................................................................................See Table 1
Impact reaction ...........................................................................Hydraulic clutch
Manual manoeuvre ............................................................................ Release key
Max no. manoeuvres ......................................................................500 / 24hours
Thermal protection ............................................. 160° C..............................320° F
Environmental conditions ...... da -10 °C a +60° C................da 14° a 140° F
Degree of protection ......................................................................................IP 67
Controller weight:
SUB 220N ...........................................................(~22 kg).........................~48.50 lb
SUB G 240N .......................................................(~24 kg).........................~52.91 lb
Oil ...................................................................................................................IDROLUX
Dimensions .................................................................................................. See fig.2
(*) Special voltages available on request.
www.metalines.com
INSTALLATION MANUAL
6) ACTUATOR INSTALLATION
6.1) Preliminary checks
Check that:
- The leaf structure is sturdy and rigid.
- The upper hinge is in working order and possibly adjustable.
- A hole can be dug to lay the case under the hinge-pivot, or to one
side of the hinge-pivot for slide arm installation.
- The leaf ground stop plates are fitted.
- Repair or replace all faulty or worn components.
Fig.3 illustrates an exploded view of the installation. Automation reliability
and safety are directly affected by the condition of the gate structure.
6.2) Electrical installation setup
Set up the electrical installation as shown in fig.4, making reference to
the current standards for electrical installations. Keep the mains supply
connections definitely separate from the service connections (photocells,
electric edges, control devices, etc.).
WARNING: For connection to the mains, use a multipolar cable of the
type provided for by the standards (UL1015). Connect the control and
safety devices in compliance with the previously mentioned installation
standards. Fig.4 shows the number of connections and the cross section
for power supply cables about 328 ft (100 m) long; for greater lengths,
calculate the cross section needed for the true automation load.
6.3) Main automation parts (Fig.4):
I)
Type-approved adequately rated omnipolar circuit-breaker
with at least 3-mm contact opening, provided with protection
against overloads and short circuits, suitable for cutting out
automation from the mains. If not already installed, place a
type-approved omnipolar circuit-breaker with a 0.03A threshold
just before the automation system.
Qr)
Control panel and incorporated receiver.
SPL)
Preheating board for operation with temperature lower than
5°C (optional).
S)
Key selector.
AL)
Blinker with tuned antenna.
M)
Controller.
E)
Electric lock.
Fte)
External photocells (emitting section).
Fre)
External photocells (receiving section).
Fti)
Internal photocells with CF posts (emitting section).
Fri)
Internal photocells with CF posts (receiving section).
T)
1-2-4 channel transmitter.
RG58)
Cable for antenna.
D)
Connector block.
The connector block (fig. 6) must always be positioned
higher than the motor. In fact, as the controller is perfectly
-1
sealed, the tank is made to breathe through the actuator
supply cable.
6.4) Cementation of the foundation case (under the hinge-pivot)
The case must be cemented under the hinge-pivot, keeping in mind that
the actuator bearing shaft must be perfectly aligned to the leaf rotation
2
axis. If the gate is provided with fixed hinges, disassemble it and remove
the lower hinge. If the leaf is high enough from the ground and cannot be
removed, proceed to supporting it by means of a shim placed between
the ground and the leaf during installation. If the gate is provided with
adjustable hinges, remove the lower hinge, loosen the upper one and
move the leaf to the side. If the gate has been newly manufactured, fit
an upper hinge which can be adjusted.
- Dig a foundation hole having the dimensions shown in fig.5.
- Provide a drainage pipe (fig.6) for rainwater in order to prevent
stagnation inside the foundation case. Lay a raceway for the power
supply cable as far as connector block "D"
- Lay a strong foundation on the bottom (fig.5) where to bury the hooks
of foundation case "P". The dimensions for positioning plate "P" are
defined in fig.5. Let the cement harden for the time needed.
- Rest the actuator on base "P", with its shaft perfectly aligned to the leaf
axis (fig.7), and weld four angle bars "A" in correspondence with the
ENGLISH
11
SUB-UL