Transportation At Frost; Service; General; Maintenance Diagram General - Dibo PTL Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TRANSPORTATION AT FROST

Replace the water sucking hose by a short piece hose and hang it with his end
in the anti-frost, so the machine can suck the anti-frost. Take the lance from the
gun and operate the machine. Spray until there comes anti-frost out of the gun.
The machine is now filled with anti-frost, stop the machine.
Tip: Because the catch of the outgoing anti-frost
water, this can be re-used afterwards.

Service

GENERAL

all maintenance activities must happen at an disconnected machine and hoses
without pressure. Checking the electric components can happen exclusively by
an expert. Exclusively accessories and replacement components which have
been approved by the manufacturer can be used. Directly after the activities all
securities- and protection parts must be assembled, before the machine is put
into functioning. "a golden rule" that contributes to a perfectly working machine
with few problems, is well the following::
 
A daily control and cleaning of the machine frequently do wonders!
To be able to guarantee a perfectly working system, one has first necessary a
reliable and technical well considered machine, which is then faced secondly
at regular times with a thorough maintenance. Therefore the experience and
the "know-how" of DiBo a technical good working machine is insured and
large maintenance turns can be carried out by experienced DiBo technicians
by means of appointment or maintenance contract, we can suppose in advance
that it is satisfied to these two points.
MAINTENANCE DIAGRAM
General
1
The user can carry out only those actions for which in this book authorisation
are given. Each other act has been prohibited! For the maintenance turns of
burner kettle, high pressure pump, combustion engines and of components
which have to do with the security, one must contact our DiBo technicians.

Periodic maintenance

2
Control of the electric cables, high and low pressure
hoses and coupling and control of the oil level.
Refreshing reduction gearbox oil.
all following refreshments of pump oil / reduction
Maintenance engine (oil replace).
Clean air filter/exhaust. Replace oil filter/spark plug(s)
See also added motor manual for all other mainte-
nance items which need to happen. .
Extra control/replacement of joints, valves, o- rings
by acknowledged DiBo- technicians!
DiBO 23
DESCRIPTION
Refreshing pump oil.
Cleaning water filter.
gearbox oil.
E N
S E R V I C E    
PERIOD
after each use.
First 50 hours.
First 50 hours.
Each 50 hours/each
month.
Each 400 hours/
yearly.
First 5 hours & next
50 hours.
yearly.
pay attention, shorter
maintenance inter-
vention necessary to
the motor!
Each 600 hours

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1.780.040

Table des Matières