Endress+Hauser RMA 422 Mise En Service page 69

Masquer les pouces Voir aussi pour RMA 422:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Green
Red
Effect
LED
LED
On
Flash The 7
segment
display
shows a text
Display
shows:
E 201
"
"
A measured
value or
NNNNN
"
" is
shown in the
display
The display
shows a
meas. value
UUUUU
or "
A meas.
Value or
-----
"
" is
shown in the
display
The 7
segment
display
shows a
meas. value
The 7
segment
display
shows a
meas. value
Cause
The unit is in analogue output or alarm
set point relay simulation mode.
Both analogue inputs are switched off.
Cable open circuit monitor active -
Connection to the sensor is interrupted
on a connection of 4...20 mA, this means
the current is under
3.60 mA.
Below range -
The measured signal connected to the
analogue input is >10% below the valid
measurement range. Is not valid for the
4...20 mA input range.
Over range -
The measured signal connected to the
analogue input is >10% over the valid
"
measurement range. Is not valid for the
4...20 mA input range.
Faulty signal monitoring -
On a 4...20 mA input range the signal
connected to the input is outside the
specified range ( >3.60 ...
<3.85 mA or >20.4 ... <21.0 mA)
The measured value calculated from the
two input signals lies below -19999 or
above 99999.
The measured value allocated to the
analogue output is below the -10% value
of the analogue output.
Process transmitter
Fault
Solution
code
E 200
End simulation mode.
E 201
Activate at least one
analogue input.
E 210
Please check the
connection of the
sensor at analogue
input 1
E 220
Please check the
connection of the
sensor at analogue
input 2.
E 210
Please check the
connection of the
sensor at analogue
input 1.
E 220
Please check the
connection of the
sensor at analogue
input 2
E 212
Please check the
connection of the
sensor at analogue
input 1.
E 222
Please check the
connection of the
sensor at analogue
input 2.
E 213
Please check the
function of the sensor
connected to input 1.
E 223
Please check the
function of the sensor
connected to input 2.
E 230
Check if the input
signals are valid, or
check the scaling of
the two analogue
inputs.
Please check if the
input signals are valid
or whether the
calculated values are
within a valid range,
or allocate a smaller
value to the 0% value
of the
E 240
analogue output 1 ,
E 250
analogue output 2.
67