a safety cable.
Fig. 13. Operate the pump within the rated working limits.
8. MAINTENANCE
Make sure the pump is unplugged or, for three-phase
pumps, that the main switch is disconnected before car-
rying out any maintenance operations.
4" and 5" pumps do not require any routine maintenance.
Periodically check the delivery pressure and the current
absorption.
A delivery pressure decrease may be caused by pump
wear.
Increased current absorption indicates abnormal mecha-
nical fiction in the pump or motor.
9. TROUBLESHOOTING
Possible causes and remedies
THE PUMP DOES NOT DELIVER.
• The water level has dropped. Wait for the level to be
restored.
• No power, the automatic switch has tripped.
Find the problem and reset the switch.
• Blown fuses (three-phase pump). Replace the fuses.
• Thermal protection activation. Reset the protection (For
5" pumps, it will reset automatically after the motor has
cooled).
• Clogged check valve.
• Sand in the pump. Extract the pump and have it overhau-
led.
REDUCED CAPACITY AND PRESSURE.
• Sand in the pump. Extract the pump and have it overhauled.
• Three-phase pump rotates in the wrong direction. Switch
two phase conductors in the control panel
• System leaks. Locate the leaks and repair them.
• Worn pump. Extract the pump and overhaul it.
THE PUMP STARTS AND STOPS TOO FREQUENTLY.
• Probable activation of level probes/float (pump capacity
higher than well capacity). Reduce water supply to the
user.
• Application with surge tank: pressure switch not set cor-
rectly or surge tank of inadequate capacity or insufficient
water cushion. Adjust the setting. Replace the tank with
one of greater capacity.
• Excessive absorption of current by the motor. Mechani-
cal friction. Extract the pump and have it overhauled.
• Liquid temperature too high (GSC single-phase).
Activation of the built-in motor protector.
6
SENECA FALLS, 10/12/2010
PATRICK MOYER
(DIRETTORE ENGINEERING AND R&D)
rev.00
10. EC DECLARATION OF CONFORMITY
EC DECLARATION OF CONFORMITY
ITT WATER TECHNOLOGY, INC., WITH HEADQUAR-
TERS IN 2881 EAST BAYARD STREET – SENECA FAL-
LS – NEW YORK 13148 – U.S.A., HEREBY DECLARES
THAT THE FOLLOWING PRODUCTS
ELECTRIC PUMP (1~, 3 ~, 50 HZ, 60 HZ) (SEE LABEL
ON FIRST PAGE)
# 1 GSC
# 2 GGS
FULFILS THE RELEVANT PROVISIONS OF THE FOL-
LOWING EUROPEAN DIRECTIVES
• MACHINERY 98/37/EC (➭ 28.12.2009), 2006/42/EC
(29.12.2009 ➭)
• ELECTROMAGNETIC COMPATIBILITY 2004/108/EC
AND THE FOLLOWING TECHNICAL STANDARDS
# 1 EN 809, EN 60335-1, EN 60335-2-41, EN 61000-6-
1:2007, EN 61000-6-3:2007
# 2 EN 809, EN 60204-1, EN 61000-6-1:2007, EN
61000-6-3:2007
THE
TECHNICAL
FILE
ITT WATER TECHNOLOGY, INC. .
EC DECLARATION OF CONFORMITY
ITT WATER TECHNOLOGY, INC., WITH HEADQUAR-
TERS IN 2881 EAST BAYARD STREET – SENECA FAL-
LS – NEW YORK 13148 – U.S.A., HEREBY DECLARES
THAT THE FOLLOWING PRODUCTS
PUMP (SEE LABEL ON FIRST PAGE)
GGS
FULFILS THE RELEVANT PROVISIONS OF THE FOL-
LOWING EUROPEAN DIRECTIVES
• MACHINERY 98/37/EC (➭ 28.12.2009), 2006/42/EC
(29.12.2009 ➭)
AND THE FOLLOWING TECHNICAL STANDARDS
EN 809
THE TECHNICAL FILE IS AVAILABLE FROM ITT WATER
TECHNOLOGY INC. .
SENECA FALLS, 10/12/2010
PATRICK MOYER
(DIRECTOR OF R&D AND ENGINEERING)
rev.00
« ORIGINAL »
IS
AVAILABLE
FROM
« ORIGINAL »

Publicité

loading

Ce manuel est également adapté pour:

Goulds ggs