Masquer les pouces Voir aussi pour 8026:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.5.2 Assemble the flow transmitter SE36 on
the sensor-fitting S070 or S077
SE36
1
2
3
S077
S070
Fig. 10:  Assembling the flow transmitter SE36 with sensor-fitting S070 or 
S077
20
1: Insert the flow transmitter
SE36 in the sensor holder.
2: Turn the flow transmitter
SE36 by a quarter turn.
3: Secure the flow transmitter
SE36 and the sensor-fitting
S070 or S077 by tightening
the 2 screws to a max. torque
of 1 Nm.
English
Type 8026 - 8036 - SE36
Installation and wiring
7.5.3 complete the installation of the flow
transmitter SE36 with sensor-fitting
S070 or S077
Wire the device (see chap. 7.6) and supply power to the device.
Set the K-factor or determine it through a Teach-In procedure
(see chap. 8.8.8).
7.6

Wiring

Danger
risk of injury due to electrical voltage.
▶ Shut down and isolate the electrical power source before carry-
ing out work on the system.
▶ Observe all applicable accident protection and safety regula-
tions for electrical equipment.
• Use a high quality electrical power supply (filtered and
regulated).
• Make sure the installation is equipotential (see
chap. 7.6.3).
• Use a shielded cable.
• Once the device is wired, set the "HWMode" parameter
depending on the wiring carried out, sink/NPN or source/
PNP (see chap. 8.8.3).