Installation Of A 8036 On A Pipe - Burkert 8026 Guide Rapide

Masquer les pouces Voir aussi pour 8026:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.4
installation of a 8036 on a pipe
Danger
risk of injury due to high pressure in the installation.
▶ Stop the circulation of fluid, cut off the pressure and drain the
pipe before loosening the process connections.
risk of injury due to the nature of the fluid.
▶ Respect the prevailing regulations on accident prevention and
safety relating to the use of aggressive fluids.
Follow the next steps to install the flowmeter 8036 properly:
7.4.1 install the sensor-fitting S030 in the
pipe
Select a sensor-fitting S030 adapted with the fluid velocity.
To select a fitting, please refer to the chart in the technical
data sheet of the related fitting.
Choose a place for the sensor-fitting S030 on the pipe so that:
- air bubbles do not appear in the pipe, in the section around the
sensor (Fig. 5, chap. 7.3.1).
- the pipe is always filled in the section around the sensor (Fig. 5,
chap. 7.3.1).
18
English
Type 8026 - 8036 - SE36
Installation and wiring
attention
risk of damage when installing the fitting.
▶ Respect the installation instructions given in the user manual for
the fitting.
Install the sensor-fitting S030 in the pipe so that the paddle
wheel axis is horizontal (Fig. 6, chap. 7.3.1)
7.4.2 Assemble the flow transmitter SE36 on
the sensor-fitting S030
SE36
1
2
S030
3
Fig. 8: 
Assembling the flowmeter 8036
1: Insert the flow transmitter
SE36 in the sensor holder.
2: Turn the flow transmitter SE36
by a quarter turn.
3: Secure the flow transmitter
SE36 and the sensor-fitting
S030 by tightening the screw to
a max. torque of 1 Nm.