Performance Data Sheet - GE PVD Serie Manuel Du Propriétaire Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Performance Data Sheet

Model: GE Appliances XWF
sheet and at iapmort.org.
Substance Tested for Reduction
Chlorine Taste and Odor
Chloramine Taste and Odor
Particulate, Class I
Cysts
Lead
Mercury
Asbestos
Toxaphene
VOC (Chloroform surrogate chemical)
Alachlor
Carbofuran
carbon tetrachloride
chloropicrin
1,2-dichloroethane
1,1-dichloroethylene
cis-1,2-dichloroethylene
trans-1,2-dichloroethylene
1,2-dichloropropane
cis-1,3-dichloropropylene
dinoseb
Endrin
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
heptachlor (H-34, Heptox)
heptachlor epoxide
hexachlorobutadiene
hexachlorocyclopentadiene
Lindane
methoxychlor
pentachlorophenol
Styrene
1,1,2,2-tetrachloroethane
Tetrachloroethylene
Toluene
2,4,5-TP (silvex)
tribromoacetic acid
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethylene
bromoform
bromodichloromethane
chlorodibromomethane
xylenes
Meprobamate
Atenolol
Metolachlor
Trimethoprim
Linuron
TCEP
TCPP
Phenytoin
Ibuprofen
Naproxen
Estrone
Bisphenol A
Nonyl phenol
44
Influent challenge
Maximum permissible
concentration
product water
0.5
0.15
0.01
0.006
0.002
0.003
0.300
0.015
0.050
0.001
0.100
0.003
0.081
0.001
0.190
0.001
0.078
0.0018
0.077
0.001
0.015
0.0002
0.110
0.0017
0.052
0.00002
0.08
0.001
0.040
0.001
0.088
0.0048
0.083
0.001
0.170
0.0005
0.086
0.001
0.080
0.001
0.079
0.001
0.170
0.0002
0.053
0.00059
0.088
0.001
0.044
0.00002
0.022
0.0005
0.024
0.0006
0.0096
0.0002
0.015
0.0003
0.0072
0.0001
0.0082
0.0003
0.025
0.00001
0.0107
0.0002
0.044
0.001
0.060
0.000002
0.055
0.00001
0.050
0.0001
0.096
0.001
0.120
0.004
0.150
0.0005
0.081
0.001
0.081
0.001
0.078
0.001
0.270
0.0016
0.042
0.001
0.160
0.0005
0.084
0.0046
0.150
0.0005
0.180
0.0010
0.300
0.015
0.300
0.015
0.300
0.015
0.070
0.001
60
30
200
200
200
20
20
700
700
30
60
20
20
300
200
Avg %
Application Guidelines/Water Supply Parameters
Reduction
96.9
Water Supply
96.9
Water Pressure
91.4
Water Temperature
>99.99
Capacity
98.85
96.3
It is essential that the manufacturer's recommended installation,
>99
maintenance and filter replacement requirements be carried out for the
86.95
product to perform as advertised. See Installation Manual for Warranty
99.7
information.
> 98
NOTE: While the testing was performed under standard
> 97
> 99
laboratory conditions, actual performance may vary.
> 99
98
of replacement elements please visit our website at
> 99
gewaterfilters.com.
99
98
> 99
WARNING
> 99
> 98
• Do not use with water that is microbiologically unsafe
95
or of unknown quality without adequate disinfection
> 99
before and after the system. Systems certified for cyst
> 99
reduction may be used on disinfected water that may contain
> 99
filterable cysts.
> 99
> 99
99
NOTICE
99
To reduce the risk of water leakage or flooding, and to
> 99
ensure optimal filter performance:
> 99
• Read and follow use instructions before installation and
98
use of this system.
98
98
• Installation and use MUST comply with all state and local
98
plumbing codes.
99
• Do not install if water pressure exceeds 120 psi (827
96
kPa). If your water pressure exceeds 80 psi (552 kPa), you
>99
must install a pressure-limiting valve. Contact a plumbing
98
professional if you are uncertain how to check your water
> 98
pressure.
> 99
> 99
• Do not install where water hammer conditions may occur.
> 99
If water hammer conditions exist you must install a water
> 99
hammer arrester. Contact a plumbing professional if you are
> 97
uncertain how to check for this condition.
> 99
• Do not install on hot water supply lines. The maximum
> 99
> 99
(38º C).
> 99
99
• Protect filter from freezing.
> 98
> 99
• Change the disposable filter cartridge every six months or
95
sooner if you observe a noticeable reduction in water flow
> 99
rate.
> 99
95
95
recommended intervals may lead to reduced filter
95
performance and cracks in the filter housing, causing water
>99
leakage or flooding.
95.5
95.9
53 and 401 for the reduction of the substances listed below.
98.6
The concentration of the indicated substances in water
98.6
98.7
entering the system was reduced to a concentration less
96.1
than or equal to the permissible limit for water leaving the
96.6
98.1
98.1
96
95.9
96.5
97.1
99.1
97.3
0.5 gpm (1.89 lpm)
Potable Water
25-120 psi (172-827 kPa)
170 gallons (643.5 liters)
To reduce the risk associated with
ingestion of contaminants:
XWF System is certified by IAPMO R&T
against NSF/ANSI Standards 42,53, and 401
for the reduction of claims specified on the
performance data sheet and at iapmort.org.
49-1000332 Rev. 0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gve serie

Table des Matières