Performance Data Sheet - GE Appliances Cafe CFE Serie Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Performance Data Sheet

Model: GE Appliances RPWFE
Use Replacement Cartridge RPWFE.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity 170 Gallons (643.5 Liters). Contaminant Reduction Determined by NSF testing.
Substance Tested
for Reduction
Average Influent
Chlorine Taste and Odor
2.0 mg/L
Nominal Particulate
Class I, , ≥0.5 to < 1.0 μm 7,633,333 pts/mL At least 10,000 particles/mL
Asbestos
109 MFL
Atrazine
0.009 mg/L
Benzene
0.016 mg/L
Carbofuran
0.08 mg/L
Cyst*
104,750 cysts/L
Lead pH @6.5
0.140 mg/L
Lead pH @8.5
0.158 mg/L
Mercury @ pH 6.5
0.006 mg/L
Mercury @ pH 8.5
0.006 mg/L
Lindane
0.002 mg/L
P-Dichlorobenzene
0.222 mg/L
Toxaphene
0.015 mg/L
2, 4-D Reduction
0.218 mg/L
VOC
0.278 mg/L
*Based on the use of Cryptosporidium parvum oocysts.
The following pharmaceutical reduction claims have not been certified by NSF International. Claims tested and verified
by independent laboratory:
Substance
Reduction
Average Influent
Atenolol
1088 ng/L
Fluoxetine
845 ng/L
Ibuprofen
898 ng/L
Progesterone
945 ng/L
Trimethoprim
403 ng/L
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.89 lpm)
Water Supply
Potable Water
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform
as advertised. See Installation Manual for Warranty information.
NOTE:
While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWFE. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before and after the system.
Systems certified for cyst reduction may be used on disinfected water that may
contain filterable cysts. EPA Establishment Number 070595-MEX-001.
NOTICE
To reduce the risk of water leakage or flooding, and to ensure optimal filter
performance:
• Read and follow use instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
Tested and certified by NSF International
against NSF/ANSI Standard 42 and Standard 53
in model GE Appliances RPWF and GE Appliances
RPWFE for the reduction of the claims specified
on the performance data sheet.
REPLACEMENT
ELEMENT
49-60791-2
NSF specified
Avg %
Challenge Concentration
Reduction
2.0 mg/L ± 10%
97.4%
99.0%
7
8
10
to 10
fibers/L; fibers
greater than 10μm in length
99.99%
0.009 mg/L ± 10%
94.4%
0.015 mg/L ± 10%
96.4%
0.08 mg/L ± 10%
98.8%
Minimum 50,000 cysts/L
99.99%
0.15 mg/L ± 10%
99.3%
0.15 mg/L ± 10%
98.3%
0.006 mg/L ± 10%
91%
0.006 mg/L ± 10%
88.3%%
0.002 mg/L ± 10%
99%
0.225 mg/L ± 10%
99.8%
0.015 mg/L ± 10%
93.5%
0.210 mg/L±10%
99.9%
0.300 mg/L ± 10%
97.7%
NSF specified
Avg %
Challenge Concentration
Reduction
N/A
99.5%
N/A
99.4%
N/A
98.8%
N/A
99.4%
N/A
99.5%
Average Product
Max Permissible
Water
Product Water
Concentration
Concentration
0.05 mg/L
N/A
71,850 pts/ml
N/A
<1 MFL
N/A
0.0005 mg/L
0.003 mg/L
0.001 mg/L
0.005 mg/L
0.001 mg/L
0.04 mg/L
3 cyst/L
N/A
0.001 mg/L
0.010 mg/L
0.002 mg/L
0.010 mg/L
0.0003 mg/L
0.002 mg/L
0.0007 mg/L
0.002 mg/L
0.00002 mg/L
0.0002 mg/L
0.0005 mg/L
0.075 mg/L
0.001 mg/L
0.003 mg/L
0.0001 mg/L
0.07 mg/L
0.0015 mg/L
N/A
Average Product Water
Concentration
5.0 ng/L
5.0 ng/L
9.9 ng/L
5.5 ng/L
2.0 ng/L
Water Pressure
25-120 psi (172– 827 kPa)
Water Temperature
33º F - 100º F (0.6º C - 38º C)
• Do not install if water pressure exceeds 120 psi (827 kPa). If your water pressure
exceeds 80 psi (552 kPa), you must install a pressure-limiting valve. Contact
a plumbing professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
• Do not install on hot water supply lines. The maximum operating water
temperature of this filter system is 100º F (38º C).
• Protect filter from freezing. Drain filter when temperatures drop
below 33ºF (0.6ºC).
a noticeable reduction in water flow rate.
lead to reduced filter performance and cracks in the filter housing, causing water
leakage or flooding.
NSF Reduction
NSF
Requirements
Test Report
≥50%
J-00102044
≥85%
J-00106249
≥99%
J-00102069
N/A
J-00102058
N/A
J-00102065
N/A
J-00102059
≥99.95%
J-00102057
N/A
J-00102052
N/A
J-00102053
N/A
J-00102054
N/A
J-00104087
N/A
J-00102063
N/A
J-00102067
N/A
J-00102061
N/A
J-00102064
≥95%
J-00102070
Max Permissible
Product Water
NSF
Concentration
Test Report
N/A
J-00103221
N/A
J-00103221
N/A
J-00103726
N/A
J-00103727
N/A
J-00103221
RPWFE

Publicité

Chapitres

Table des Matières
loading

Table des Matières