Info and menu parameters
WHF00
WARM
HOLDING
FUNCTION
BAS09
TIME OF DAY
BAS10
DATE
BAS15
MIN TEMP
HEAT
SOURCE
BAS16
DAYLIGHT
SAVING TIME
PAR
SET VALUE
ZIR
CIRCULATION
ZIR00
CIRCULATION
MODE
ZIR01
TEMP.REDUCE
TSET CIRC.
ZIR04
TBZ SENSOR
TYPE
ZIR05
TOLERANCE
CALI. CIRC
04/2021 Item no. 215790 EA no. 1321
Option:
The standby/warm holding func-
Standby/
tion keeps the heat exchanger at
warm holding
a standby temperature in order to
function
ensure rapid domestic hot water
preparation.
Time of day
The time of day is automatically
adjusted to daylight saving time
and to standard time.
Date
If the temperature in the tank is <
Primary/tank
minimum
setting, the station is switched
temperature
off and an "11" status message is
generated.
Daylight
Suppression of the automatic
saving time
changeover from daylight saving
time to standard time:
n
off: automatic changeover
from daylight saving time to
standard time
n
on: automatic changeover
from daylight saving time to
standard time is suppressed
Adjuster is visible if circulation mode ZIR00 (05:006) is not set to 0.
Circulation pump function (see above for basic
parameters)
Setpoint
Setpoint reduction for circulation
reduction for
return, results in the circulation
circulation
setpoint temperature that is to be
return
reached at sensor TBZ. TBZset =
TWWset - TWWset_return
n
TBZ circula-
0: NTC 5K
tion sensor
n
1: PT 1000
selection,
sensor type
Circulation
Circulation flow rate tolerance.
flow rate tol-
Maximum permissible deviation
erance
below the flow rate measured
values in relation to calibration.
on/off
00:00
yyyy
dd:mm
0...90
on/off
0...3
0...90
0...1
0...100
Operating instructions
ES 5941
25
05:113
-
0
02:72
-
0
02:070
°C
25
05:058
-
25
04:003
-
0
05:006
°C
0
05:054
-
25
05:088
%
25
36:011
29