Operational Summary - Nikon PROSTAFF 3 Manuel D'utilisation

Télémètre laser
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operational summary

Caution—use of controls or adjustments or
En
performance of procedures other than those
Fr
specified herein may result in hazardous radiation
exposure
Es
1. Install a battery in the battery chamber. (See
Pt
"Changing Batteries")
2. Rubber eyepiece cup
Eyeglass wearers: Roll up the rubber eyepiece cup
and use.
Non-eyeglass wearers: No need to roll up the rubber
eyepiece cup for use.
3. Diopter adjustment
Adjust diopter to obtain a clear image in the LCD.
First, rotate the diopter adjustment ring
counterclockwise until it comes to a complete
stop. Next, turn on the power to activate the LCD
when you look through the PROSTAFF 3. Rotate the
diopter adjustment ring clockwise until the display
comes into focus.
If the diopter is not adjusted to correspond to your
eyesight, you may not be able to clearly focus your
subject.
4. Measuring
Note: Depressing and holding down the POWER
button causes all symbols to be displayed in
the LCD panel. After you remove your finger
from the POWER button, the last-used setting
is displayed. (If you briefly press the POWER
button then remove your finger, the LCD panel
may display the last-used setting without
displaying all of the symbols. This is not a
malfunction or other problem.)
Before measuring, be sure to confirm unit setting.
12
POWER
LCD is illuminated
Align the reticle
with the target
For continuous
distance
measurement (up
to 20 seconds),
POWER
keep button
depressed.
appears
or
Indication
remains
illuminated
for 8 sec.
8 seconds pass without operation *
Power off: LCD indications disappear
* Power turns off automatically 8 seconds after the last
operation.
☆【Continuous measurement mode】
Depressing the POWER button allows you to perform
continuous measurement for 20 seconds.
Appears while performing measurements.
5. Selecting display unit (default setting is yards.)
Yard [
]
Meter [
]
1. Confirm the internal LCD panel is on.
2. Press and hold the MODE button (more than two
seconds.)
3. When display unit has switched, release the MODE
button.
4. Repeat steps 2 and 3 until your desired mode is
displayed.
5. When you have completed setting, results will
be converted and displayed in the your selected
measurement unit.
6. Distance display
The PROSTAFF 3 features Distant Target Priority
System.
When obtaining different results from a single
measuring operation, the PROSTAFF 3 will display
the distance to the farthest target on the LCD panel.
ex.) When measuring a tree standing in front of a
house;
Tree
Fence
House
Distance to Target
115m
123m
128m
"128m" (distance to the house) will be displayed.
This mode has applications for hunting in heavy
wooded areas.
7. Low battery indication
Flashing
indicates that the battery power is
low and battery should be replaced. (See "Changing
Battery")
En
Fr
Es
Pt
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Prostaff 3 realtee

Table des Matières