General Data - Ingersoll Rand IRN 15 HP Manuel D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour IRN 15 HP:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

60/50Hz
COMPRESSOR
Nominal pressure
PSIG (bar)
Flow rate @ 150 PSIG (10.3 bar)
3
1, 4
ACFM (m
/MIN)
Flow rate @ 125 PSIG (8.6 bar)
3
2, 4
ACFM (m
/MIN)
Flow rate
3
@ 115 PSIG (8 bar) ACFM (m
Airend discharge temperature.
Ambient operating temperature
(min.) → (max.)
MOTOR
Nominal power
Insulation class
COOLING SYSTEM − Air cooled
Cooling air flow
Maximum ∆P in air ducts
Compressed air outlet ∆T

GENERAL DATA

Separation volume
Coolant capacity
Weight − base mount unit
Weight − 120 gallon Receiver mounted
Weight − 240 gallon Receiver mounted
Weight − 500 Litre Receiver mounted
Weight − 750 Litre Receiver mounted
DRYER ENGINEERING DATA
Electrical protection class (std)
Factory refrigerant charge (oz/g)
Refigeration type
1 Assuming a 5 psi (0.34 bar) pressure drop through the TAS module.
2 Assuming a 8 psi (0.55 bar) pressure drop through the TAS module.
3 Assuming a 9 psi (0.62 bar) pressure drop through the TAS module.
4 Flow rate will decrease as DP through the TAS module increases.
http://air.ingersollrand.com
TAS
75
(2.12)
80
(2.27)
84
3, 4
/MIN)
(2.38)
N/A
INSTALLATION / HANDLING
IRN 20HP/ 15 kW
non−TAS
150
(10.34)
77
(2.18)
83
(2.35)
87
(2.46)
228_F (109_C) Trip point
35_F (+2_C) → 104_F (+40_C)
20HP / 15kW
3
1900ft
/min (53.8m
0.25 inWg (6.4mmH
15_F (8.3_C)
1.8 gallons (7 Litres )
3.4 gallons (13 Litres )
1350 lbs (612 kg)
1720 lbs (780 kg)
1891 lbs (858 kg)
1772 lbs (804 kg)
1891 lbs (858 kg)
50 / 60Hz
NEMA 1
(IP 20)
23.5 oz
IRN 25HP / 18.5 kW
TAS
150
(10.34)
92
(2.61)
99
(2.80)
105
(2.97)
25HP / 18.5kW
F
3
/min)
O)
2
N/A
667 g
134 A
23
non−TAS
94
(2.66)
102
(2.89)
108
(3.06)
20_F (11_C)
en

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Irn 20 hpIrn 25 hpIrn 22 hpIrn 30 hpIrn 40 hp

Table des Matières