In single-sensor mode, the sauna control unit is operated with the heater sensor
with excess temperature fuse (F1) only. This is included in the scope of delivery.
In single-sensor mode, the sauna control unit only displays the set temperature
as standard. The actual temperature is not displayed. Should the sauna control
unit display the temperature above the heater (F1) as an actual temperature
in single-sensor mode, it must be activated when starting up for the first time
(see 8.2. Settings in the technician menu on page 28)
The maximum humidity level which can be set in single-sensor mode is based
on the temperature above the heater and the humidity is timed. Only the set
value for the humidity level (in % of relative humidity) is displayed by the sauna
control unit. The actual humidity level in the sauna room when humidity is timed
depends on the size of the room and the evaporator capacity, and may deviate
from the set value.
Two-sensor mode with bench sensor (F2)
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
the temperature measured by the bench sensor as the actual temperature.
In two-sensor mode with bench sensor, the humidity is timed. Only the set
value for the humidity level (in % of relative humidity) is displayed by the sauna
control unit. The actual humidity level in the sauna room when humidity is timed
depends on the size of the room and the evaporator capacity, and may deviate
from the set value.
Two-sensor mode with humidity temperature sensor (FTS2)
When a humidity temperature sensor is used in two-sensor mode, the sauna
control unit displays the temperature which is measured by the humidity tem-
perature sensor as the actual temperature.
In two-sensor mode with humidity temperature sensor, the evaporator is regulated
in accordance with the humidity level measured in the sauna room. The actual
value for the humidity level (in % of relative humidity) is displayed by the sauna
control unit.