8 Technical specifications

8.1

Operating conditions

The stated outputs of the generating sets are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
Generating set performance is reduced by approximately 4% for every additional 10° C and/or approximately 1% for every
additional 100m in altitude. Generating sets can only operate while stationary.
8.2
Capacity of the generating set
Before connecting and operating the generating set, calculate the electrical power required by the devices to be used (in watts)*. To
ensure optimal operation, the total wattage of devices used at the same time must be:
- greater than 60% of the generating set's rated load (risk of overload);
- less than the generating set's rated load during continuous operation (risk of overload).
If the generating set is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly.
Damage caused in this way will not be covered by the warranty.
*This load is usually indicated in the technical specifications or on the device manufacturer's plate. Some devices require a higher
load when starting. This minimum required power must not exceed the generating set's maximum power.
8.3

Generating set identification

The generating set identification plate is affixed to the outside of the enclosure.
(C)
(D)
(B)
(E)
Serial numbers will be required when requesting troubleshooting advice or spare parts.
To keep them safe, note down the serial number of the generating set below.
Generating set serial number:......../.............. - ........................ - .........
8.4
Specifications
Model
Max power/Rated power
Acoustic pressure level at 1 m/measurement uncertainty
Engine type
Recommended fuel/fuel tank capacity
Recommended oil/oil sump capacity
Oil cut-out*
Direct current
Alternating current
Circuit breaker(s)**
Socket type
Type of spark plug
Dimensions l x w x h
Weight (without fuel)
o: StandardX: Not possible
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out automatically stops the engine to prevent
any damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out
switches. In the event of an overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
(A)
(F)
(L)
(M)
(G)
(I)
(G)
(H)
(J)
(K)
INVERTER PRO 2000
1 x 2P+T - 230V - 10/16A
1 x 12V - 8A
Example of an identification plate
(A): Model
(B): CE marking
(C): Maximum
(D): Nominal power
power
(E): Power factor
(F): Earth
(G): Current
(H): Current
amperage
frequency
(I):
Current
(J):
voltage
index
(K): Reference
(L):
standard
(M):
Guaranteed acoustic power level
INVERTER PRO 2000 UK
2000 W / 1600 W
75 dB(A) / 0,70 dB(A)
Yamaha MZ80
Unleaded fuel/ 4,2 L
SAE 10W30 / 0,4 L
o
12V - 8A
230V - 7A
o
1 x 2P+T - 230V - 16A
1 x 12V - 8A
BPR6HS
49 x 28 x 44,5 cm
21 kg