Transporting And Storing The Generating Set; Storage Conditions - SDMO INVERTER PRO 2000 Manuel D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour INVERTER PRO 2000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

6 Transporting and storing the generating set

6.1
Transport and handling conditions
Before transporting the generating set, check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the
battery (if fitted). The generating set should be transported in its normal operating position; never lay it on its side. A pump unit
should be handled gently and brusque movements should be avoided. Ensure that the place where it is to be stored or used is
carefully prepared beforehand.
6.2

Storage conditions

Drain the fuel:
1.
Set the switch (A10) to
2.
Unscrew the fuel tank cap (A4) and remove the screen filter (A7-C1)
3.
Equipped with a suitable container, use a manual siphon pump to recover the fuel from the tank.
4.
Put the screen filter back inside the tank and screw the cap back onto the fuel tank.
5.
Start the generating set (see § Starting the generating set) and leave it running until it runs out of fuel.
6.
Set the switch to
7.
Turn the fuel tap and the air vent to OFF.
8.
Remove the screws (A23) and the side enclosure (A22), then place a suitable container at the fuel drain pipe outlet (C2).
9.
Loosen the fuel drain screw (C3) and allow the fuel to flow into the container.
10. Tighten the fuel drain screw once the fuel has been drained.
Lubricate the cylinders and the valves:
11. Remove the spark plug (A20-E3) (see § Checking the spark plug) and pour approximately a teaspoon of engine oil into the
spark plug opening before refitting the spark plug.
12. Refit the side enclosure by retightening it and its screws.
13. Pull the starter-recoil handle several times (A12) to distribute the oil.
Store the generating set:
14. Clean the outside of the generating set with a cloth and apply an anti-rust product to the damaged areas.
15. Cover the generating set with a protective cover and store it vertically in a clean, dry and well-ventilated place.
This procedure for storing the generating set or protecting it over the winter must be respected if the generating set is not used for a
limited period of 1 year. For longer periods of storage, it is recommended to contact your nearest agent or to start up the generating
set for a few hours every year, and respect the storage procedure after doing so.
.
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Inverter pro 2000 uk

Table des Matières