Figure 46
Electrical System
Maintenance

Electrical System Safety

Disconnect the battery before repairing the
g027939
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Battery

Removing the Battery

WARNING
Battery terminals or metal tools could short
against metal machine components, causing
sparks. Sparks can cause the battery gasses
to explode, resulting in personal injury.
• When removing or installing the battery,
do not allow the battery terminals to touch
any metal parts of the machine.
• Do not allow metal tools to short between
the battery terminals and metal parts of the
g033082
machine.
1.
Park the machine on a level surface, disengage
the blade-control switch, and move the
motion-control levers outward to the P
position.
2.
Shut off the engine, remove the key, and wait
for all moving parts to stop before leaving the
operating position.
3.
Raise the seat to access the battery.
4.
Disconnect the negative (black) ground cable
from the battery post
Note:
Retain all fasteners.
37
ARK
(Figure
47).