2.3 Plumbing,vents and drain
Connect the water supply pipe to the ¾" G inlet, screwing on the coupling (
A - Fig. 5
). Fit the circuit with
a suitable mechanical filter and a shutoff cock.
To work properly, , the oven requires drinking water with a maximum hardness of 3°F to prevent scaling
inside the cooking chamber.
Where necessary, install an appropriate water softener on the water circuit's supply line. Permanently
connect the appliance to the water distribution system. Do not use a set of separable couplings.
The admitted supply pressure range is min. 150 kPa ( 1,5 bar), max 400 kPa (4 bar).
A
Fig. 5
Vents
The vents
(B-Fig.6)
must be kept free; it cannot be blocked.
B
c
Fig. 6
Drain
Connect a funnel
(C - Fig. 6)
at the drain exit tube of the appliance to have a free downflow. The
heat resistant (100°C) drain tube used must join an open siphon. Closed connections which obstruct the
waste water are not acceptable.
34