STYLUS TRIGGER FORCE ADJUSTMENT - Gauging force
Stylus trigger force is determined
by internal spring pressure, which
is set by Renishaw. Only adjust
spring pressure in special
circumstances e.g. when the
weight of the stylus is too
great for standard pressures.
It is advisable to make adjustments
in small increments, and test the
Protective cover
results at each stage, until a
satisfactory result is obtained.
To adjust pressure, remove the
protective cap, and insert the 2mm
hexagon key into the adjuster socket.
Turn the key anti-clockwise to
Increase pressure
reduce spring pressure, this
will increase touch sensitivity.
2mm AF
Turn the key clockwise to
increase spring pressure.
Decrease pressure
Adjustment is limited in both
directions by end stops.