Storage
Storage conditions for products labelled "STERILE" are printed on the packaging label. Packaged products should be stored
in a dry, clean environment, protected from direct sunlight, pests, and extremes of temperature and humidity. Use products
in the order in which they are received ("first in, first out" principle), taking into account the expiry date indicated on the
label.
Automated Pre-disinfection/Cleaning and
Sterilization Instructions for all SATELEC
Wrenches
Cautions
Do not use steel wool or abrasive cleaners.
Avoid solutions containing iodine or with a high chlorine content.
The pH of detergents/disinfectants must be between 7 and 11.
The cleaning method for wrenches recommended by Satelec is manual or automated.
All devices must be carefully cleaned and must be sterilized after cleaning prior to use.
The sterilization parameters are only valid for correctly cleaned devices.
Wrenches must be cleaned with extreme care.
It is the responsibility of the end user to ensure that all equipment used to treat Satelec devices is properly installed,
validated, maintained and calibrated.
Whenever possible, a washer/disinfector should be used for wrenches. Prevent the overloading of wash baskets for
ultrasonic cleaning or cleaning in a washer/disinfector.
Cleaning/sterilization cycle limits
Repeated treatment cycles that include ultrasonic cleaning, manual washing and sterilization have minimal effects on
wrenches.
End of service life is normally determined by wear and damage due to use.
Important
•Soiled devices should be separated from non-contaminated devices to avoid contamination of personnel or surroundings.
•Wipe blood and/or debris from the wrenches to prevent it from drying onto the surfaces.
•Cover the wrench with a soft lint-free cloth dampened with purified water to prevent blood and/or debris from drying.
Containment and transportation
Soiled devices must be transported separately from non-contaminated devices to avoid contamination.
Preparation for pre-disinfection/cleaning
It is advisable to treat devices immediately or as soon as possible after use. Satelec devices must be treated within two
hours of use.
Pre-disinfection/pre-cleaning method
Note: The pre-disinfection/pre-cleaning method has to be performed for the wrench prior to automated cleaning.
Equipment: soft-bristled brush, soft lint-free swab, lint-free cloth, ultrasonic cleaner, washer/disinfector, enzymatic or
alkaline cleaner.