LEVEL A
LEVEL B
LEVEL C
Meter Type
2 Chan Energy Channel 1/2 Clamp-on FastStart Setup
2 Path Energy
Ch 1+2 Energy
Ch 1-2 Energy
Thickness Gauge
This Menu Chart applies to:
MLFB - 7ME3502
Siemens Industry, Inc.
Industry Automation Division
CoC Ultrasonic Flow
Hauppauge, New York
USA
Web: www.usa.siemens.com
FUE1010 IP40 (NEMA 1) Installation Menu Chart
LEVEL D
Reflexor
1
Full Site Setup
3
4
5
LEVEL E
LEVEL F
Pick Pipe Class
Enter From List
Select Pipe
N/A
Install Xdcr
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value <in>
Install Complete
Empty Pipe Set
Zero FlowAdjust
Channel Setup
Recall Site
Channel Enable
2
Create/Name Site
Site Security
Delete Site
Save/Rename Site
Pipe Data
Pick Pipe Class
Select Pipe Size
Pipe OD (in)
Pipe Material
Wall Thickness
Liner Material
Liner Thickness
Application Data
Liquid Class
Location
Service
Temp. Range
Pipe Config
Anomaly Diams
Install Xdcr
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Complete
Empty Pipe Set
Zero Flow Adjust
Operation Adjust
Damping Control
Energy Deadband
Deadband Control
Memory/Fault Set
Memory Delay (s)
Flow/Total Units
Energy Units
Volume Units
Span/Set/Cal
Span Data
Set Alarm Levels
Calib. Flowrate
Display Setup
Select Data
Data Display
Time Base
Stripchart Clear
Logger Setup
Logger Mode
Logger Data
Logger Interval
Logger Events
Display Logger
I/O Data Control
Analog Out Setup
Relay Setup
Analog Inp Setup
LEVEL G
LEVEL H
Enter From List
Enter From List
Enter From List
Enter From List
View only
View only
View Only
No/Install
Enter From List
Enter From List
Enter From List
No/Yes
Enter Site Name
On/Off
Enter From List
Enter/Clear Site Name
Enter From List
Enter From List
Numeric Entry
Enter From List
Numeric Entry
Enter From List
Numeric Entry
Select Liquid
Enter from List
Estimated Vs M/S
Numeric Entry
Viscosity (cS)
Numeric Entry
Density S.G.
Numeric Entry
Return/Supply
Heating/Cooling/Heat Pump
Enter From List
Enter From List
Numeric Entry
Enter From List
Enter From List
Enter From List
Enter From List
View Only
View Only
View Only
No/Install
Select Install
Enter From List
Enter From List
Time Average / SmartSlew
Numeric Entry
Numeric Entry
Fault/Memory
N/A
E Rate Units
Enter From List
E Rate Scale
Enter From List
Energy Tot Units
Enter From List
Energy Tot Scale
Enter From List
Energy Tot Res
Enter From List
Energy Tot Mode
Enter From List
CE Method
Flow Vol. Units
Enter From List
Flow Time Units
Enter From List
Flow Disp. Range
Autorange/High
Flow Disp. Scale
Enter From List
Total Vol. Units
Enter From List
Totalizer Scale
Enter From List
Total Resolution
Enter From List
Totalizer Mode
Enter From List
Batch/Sample Tot
Numeric Entry
Enter From List
Enter From List
Intrinsic
Kc
MultiPoint
Enter From List
Enter From List
Enter From List
Yes/No
Enter From List
Enter From List
Enter From List
Enter From List
Enter From List
Enter From List
Relay 1,2
Enter From List